W DOC AIRBUS | TSM A320F

Loss of the Automatic Control and Monitoring of the Valves and Fans


TASK 21-26-00-810-801-A
Loss of the Automatic Control and Monitoring of the Valves and Fans


1. Possible Causes
  • CARTRIDGE-AVNCS VENT FILTER [2082HM]
  • AEVC [10HQ]
  • wiring between the AEVC pin AA/1D and the ground terminal
  • C/B-AIR COND/AVNCS/VENT/MONG [3HQ]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 24-00-00-810-803-A
Circuit Breaker Tripped and/or C/B TRIPPED Warning
AMM 21-26-00-710-001
Operational Check of the Avionics Equipment Ventilation-System via MCDU
AMM 21-26-00-710-008
Operational Test to Read the CFDS for CLASS 3 Faults of the AEVC
AMM 21-26-00-710-009
Operational Test to Read the CFDS for LAST LEG REPORT of the AEVC
ASM 212601
ASM 212603
AMM 21-26-34-000-001
Removal of the Avionics Equipment Ventilation Computer (AEVC)
AMM 21-26-34-400-001
Installation of the Avionics Equipment Ventilation Computer (AEVC)
AMM 21-26-43-600-016
Discard Demister Filter Element and Filter Cartridge (LE BOZEC)
AMM 21-26-43-920-001
Discard the Filter Cartridge (PALL)
3. Fault Confirmation
Subtask 21-26-00-865-050-A
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
122VUAIR COND/AVNCS/VENT/MONG3HQY17
Subtask 21-26-00-710-050-A
B. Test
   (1) Do the reset of the AEVC (10HQ).
     (a) Open the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
     (b) Wait for five seconds.
     (c) Close the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
   (2) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
   (3) Read the LAST LEG REPORT of the AEVC AMM 21-26-00-710-009.
   (4) Read the CLASS 3 faults of the AEVC AMM 21-26-00-710-008.
4. Fault Isolation
Subtask 21-26-00-810-050-D ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message NO RESPONSE:
  • make sure that the avionics ventilation filter is not dirty. If necessary, replace the CARTRIDGE-AVNCS VENT FILTER [2082HM] AMM 21-26-43-920-001.
   (1) If the fault continues:
  • Do a check of the status of the circuit breaker (3HQ).
     (a) If the circuit breaker (3HQ) is closed:
  • Do a check for 28VDC at pin AA/1A of the AEVC (10HQ) ASM 212603.
       1 If there is 28VDC:
  • Do a check for a ground signal at pin AA/1D of the AEVC (10HQ) ASM 212601.
         a If there is a ground signal:
         b If there is no ground signal:
  • Repair the wiring between the AEVC pin AA/1D and the ground terminal.
       2 If there is no 28VDC:
  • Do a check of the wiring between the AEVC pin AA/1A and the circuit breaker (3HQ) ASM 212603.
         a If there is no continuity:
  • Repair the related wiring.
         b If there is continuity:
  • Replace the C/B-AIR COND/AVNCS/VENT/MONG [3HQ] .
     (b) If the circuit breaker (3HQ) is open:
       1 If the fault continues:
  • Replace the C/B-AIR COND/AVNCS/VENT/MONG [3HQ] .
       2 If the fault continues:
Subtask 21-26-00-810-050-E ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message NO RESPONSE:
  • Make sure that the avionics ventilation filter is not dirty. If necessary, replace CARTRIDGE-AVNCS VENT FILTER [2082HM] AMM 21-26-43-600-016.
   (1) If the fault continues:
  • Do a check of the status of the circuit breaker (3HQ).
     (a) If the circuit breaker (3HQ) is closed:
  • Do a check for 28VDC at pin AA/1A of the AEVC (10HQ) ASM 212603.
       1 If there is 28VDC:
  • Do a check for a ground signal at pin AA/1D of the AEVC (10HQ) ASM 212601.
         a If there is a ground signal:
         b If there is no ground signal:
  • Repair the wiring between the AEVC pin AA/1D and the ground terminal.
       2 If there is no 28VDC:
  • Do a check of the wiring between the AEVC pin AA/1A and the circuit breaker (3HQ) ASM 212603.
         a If there is no continuity:
  • Repair the related wiring.
         b If there is continuity:
  • Replace the C/B-AIR COND/AVNCS/VENT/MONG [3HQ] .
     (b) If the circuit breaker (3HQ) is open:
       1 If the fault continues:
  • Replace the C/B-AIR COND/AVNCS/VENT/MONG [3HQ] .
       2 If the fault continues:
Subtask 21-26-00-710-051-A
B. Do the operational test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:24:36 UTC