Galley and Lavatory Extraction Fault
TASK 21-23-00-810-801-A
Galley and Lavatory Extraction Fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-23-00-710-050-A 4. Fault Isolation
Subtask 21-23-00-810-050-A ** ON A/C NOT FOR ALL
Subtask 21-23-00-860-050-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:36 UTC
Galley and Lavatory Extraction Fault
1. Possible Causes
- GALLEY & TOILET FAN [1HU]
- RELAY-FAN POWER [2HU]
- RELAY-FAN CONTROL [3HU]
- RELAY-FAN FAULT [4HU]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 212301 | |
| AMM 21-23-51-000-001 | Removal of the Lavatory and Galley Extract Fan |
| AMM 21-23-51-400-001 | Installation of the Lavatory and Galley Extract Fan |
| AMM 21-61-00-710-001 | Operational Test of the Pack Temperature-Control System |
| ASM 216301 |
Subtask 21-23-00-710-050-A 4. Fault Isolation
Subtask 21-23-00-810-050-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message GALY & TOIL FAN OR SPLY:
Subtask 21-23-00-810-050-B ** ON A/C NOT FOR ALL - replace the GALLEY & TOILET FAN [1HU] (referred to as FAN (1HU)) AMM 21-23-51-000-001 and AMM 21-23-51-400-001.
- do a check of the RELAY-FAN POWER [2HU] and replace it if necessary ASM 212301.
- do a check of the RELAY-FAN CONTROL [3HU] and replace it if necessary ASM 212301.
- do a check of the RELAY-FAN FAULT [4HU] and replace it if necessary ASM 212301.
- do a check and repair the wiring between:
FAN (1HU) connector A/A and CB (6HU),
FAN (1HU) connector A/B and CB (6HU),
FAN (1HU) connector A/C and CB (6HU),
FAN (1HU) connector A/E and CB (5HU),
FAN (1HU) connector A/D and GND,
FAN (1HU) connector A/F and GND,
RELAY (3HU) connector A/X1 and CB (5HU),
RELAY (3HU) connector A/X2 and GND,
RELAY (4HU) connector A/X and CB (6HU),
RELAY (4HU) connector A/Z and GND,
RELAY (4HU) connector A/1 and ZC (8HK) connector AB/1C,
RELAY (4HU) connector A/A and GND ASM 212301 and ASM 216301.
A. If the test gives the maintenance message GALY & TOIL FAN OR SPLY(1HU):
Subtask 21-23-00-710-051-A - replace the GALLEY & TOILET FAN [1HU] AMM 21-23-51-000-001 and AMM 21-23-51-400-001.
- do a check of the RELAY-FAN POWER [2HU] and replace it if necessary ASM 212301.
- do a check of the RELAY-FAN CONTROL [3HU] and replace it if necessary ASM 212301.
- do a check of the RELAY-FAN FAULT [4HU] and replace it if necessary ASM 212301.
- do a check and repair the wiring ASM 212301 and ASM 216301 from:
- the FAN (1HU) to the CB (6HU),
- the FAN (1HU) to the CB (5HU),
- the FAN (1HU) to ground,
- the RELAY (3HU) to the CB (5HU),
- the RELAY (3HU) to ground,
- the RELAY (4HU) to the CB (6HU),
- the RELAY (4HU) to ground and,
- the RELAY (4HU) to the ACSC1 (47HH).
B. Do the test as given in the Para. 3.A.
5. Close-upSubtask 21-23-00-860-050-A
A. Put the aircraft back to its initial configuration.