Cabin Recirculation Fault (SDAC 1 / SDAC 2)


TASK 21-21-00-810-804-A
Cabin Recirculation Fault (SDAC 1 / SDAC 2)


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-21-00-710-001
Operational Test of the Cabin Recirculation Fans
ASM 212101
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
3. Fault Confirmation
Subtask 21-21-00-710-057-A
A. Do the operational test of the cabin recirculation fans 14HG and 15HG AMM 21-21-00-710-001.
4. Fault Isolation
Subtask 21-21-00-810-055-A
A. If the ECAM upper DU gives the warning COND L+R CAB FAN FAULT, but no maintenance message comes on:
   (1) replace the SDAC-1 [1WV1] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
   (2) If the fault continues:
   (3) If the fault continues:
  • do a check and repair the wiring ASM 212101 between:
  • the P/BSW-VENTILATION/CAB FANS (4HG)A pin B3 and SDAC-1 (1WV1)AA pin 10G and,
  • P/BSW-VENTILATION/CAB FANS (4HG)A pin B3 and SDAC-2 (1WV2)AA pin 10G.
Subtask 21-21-00-720-051-A
B. Do the test as given in the Para. 3.A.