Cabin Recirculation Fault (Fan 2 / Supply)


TASK 21-21-00-810-803-A
Cabin Recirculation Fault (Fan 2 / Supply)


1. Possible Causes
  • RECIRC FILTER CARTRIDGE 2 [4013HM]
  • P/BSW-VENTILATION/CAB FANS [4HG]
  • RELAY-FAN FAULT SUPPRESS [16HG]
  • RELAY-R FAN POWER [6HG]
  • RELAY-R FAN CONTROL [8HG]
  • RELAY-R FAN FAULT [9HG]
  • RECIRC FAN 2 [14HG]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-21-00-710-001
Operational Test of the Cabin Recirculation Fans
ASM 212101
AMM 21-21-41-000-001
Removal of the Recirculation Filter
AMM 21-21-41-400-001
Installation of the Recirculation Filter
AMM 21-21-51-000-001
Removal of the Cabin Recirculation Fans
AMM 21-21-51-400-001
Installation of the Cabin Recirculation Fans
ASM 216301
3. Fault Confirmation
Subtask 21-21-00-710-056-A
A. Do the operational test of the cabin recirculation fans 14HG and 15HG AMM 21-21-00-710-001.
4. Fault Isolation
Subtask 21-21-00-810-054-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message RECIRC FAN 2 OR SPLY:
  • make sure that the recirculation filter (4013HM) housing and the adjacent area is clean.
  • remove the RECIRC FILTER CARTRIDGE 2 [4013HM] AMM 21-21-41-000-001.
   (1) If the recirculation fan (14HG) operates correctly:
  • do a check of the recirculation filter (4013HM) for contamination.
     (a) If the filter is clogged:
     (b) If the filter is not clogged:
   (2) If the recirculation fan (14HG) does not operate:
  • do a check of the P/BSW-VENTILATION/CAB FANS [4HG] and replace it if necessary ASM 212101.
     (a) If the fault continues:
  • do a check of the RELAY-FAN FAULT SUPPRESS [16HG] and replace it if necessary ASM 212101.
     (b) If the fault continues:
  • do a check of the RELAY-R FAN POWER [6HG] and replace it if necessary ASM 212101.
     (c) If the fault continues:
  • do a check of the RELAY-R FAN CONTROL [8HG] and replace it if necessary ASM 212101.
     (d) If the fault continues:
  • do a check of the RELAY-R FAN FAULT [9HG] and replace it if necessary ASM 212101.
     (e) If the fault continues:
     (f) If the fault continues:
  • do a check and repair the wiring ASM 212101 and ASM 216301 from:
  • the FAN (14HG) to the CB (3HG),
  • the FAN (14HG) to the CB (11HG),
  • the FAN (14HG) to ground,
  • the RELAY (8HG) to the RELAY (6HG),
  • the RELAY (8HG) to ground,
  • the RELAY (9HG) to the RELAY (6HG),
  • the RELAY (9HG) to ground,
  • the RELAY (9HG) to the ZC (8HK),
  • the RELAY (16HG) to the SW (4HG) and,
  • the RELAY (16HG) to ground.
Subtask 21-21-00-810-054-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message RECIRC FAN 2 OR SPLY(14HG):
  • make sure that the recirculation filter (4013HM) housing and the adjacent area is clean.
  • remove the RECIRC FILTER CARTRIDGE 2 [4013HM] AMM 21-21-41-000-001.
   (1) If the recirculation fan (14HG) operates correctly:
  • do a check of the recirculation filter (4013HM) for contamination.
     (a) If the filter is clogged:
     (b) If the filter is not clogged:
   (2) If the recirculation fan (14HG) does not operate:
  • do a check of the P/BSW-VENTILATION/CAB FANS [4HG] and replace it if necessary ASM 212101.
     (a) If the fault continues:
  • do a check of the RELAY-FAN FAULT SUPPRESS [16HG] and replace it if necessary ASM 212101.
     (b) If the fault continues:
  • do a check of the RELAY-R FAN POWER [6HG] and replace it if necessary ASM 212101.
     (c) If the fault continues:
  • do a check of the RELAY-R FAN CONTROL [8HG] and replace it if necessary ASM 212101.
     (d) If the fault continues:
  • do a check of the RELAY-R FAN FAULT [9HG] and replace it if necessary ASM 212101.
     (e) If the fault continues:
     (f) If the fault continues:
  • do a check and repair the wiring ASM 212101 and ASM 216301 from:
  • the FAN (14HG) to the CB (3HG),
  • the FAN (14HG) to the CB (11HG),
  • the FAN (14HG) to ground,
  • the RELAY (8HG) to the RELAY (6HG),
  • the RELAY (8HG) to ground,
  • the RELAY (9HG) to the RELAY (6HG),
  • the RELAY (9HG) to ground,
  • the RELAY (9HG) to the ACSC2 (57HH),
  • the RELAY (16HG) to the SW (4HG) and,
  • the RELAY (16HG) to ground.
Subtask 21-21-00-720-050-A
B. Do the test as given in the Para. 3.A.