75-32 (PW11) - COMPRESSOR BLEED AIR
- PB.201 CONF:[21] COMPRESSOR BLEED AIR - FAULT ISOLATION PROCEDURES
-
75-32-00-810-831-A
[PW11]
[8]
HPC Bleed Valve Pressure Signal Failure Channel A -
75-32-00-810-832-A
[PW11]
[8]
LPC (2.5) Bleed Valve Actuator Mechanically Stuck Open - Track Check -
75-32-00-810-833-A
[PW11]
[8]
LPC (2.5) Bleed Valve Actuator Mechanically Stuck Closed - Track Check -
75-32-00-810-834-A
[PW11]
[8]
HPC Bleed Valve Pressure Signal Failure Channel B -
75-32-00-810-835-A
[PW11]
[8]
HPC Bleed Valve Pressure Disagreement Failure -
75-32-00-810-836-A
[PW11]
[8]
LPC (2.5) Bleed Valve/Actuator Null Shift Channel A -
75-32-00-810-837-A
[PW11]
[8]
LPC (2.5) Bleed Valve/Actuator Null Shift Channel B -
75-32-00-810-838-A
[PW11]
[8]
HPC Bleed Valve Failed Closed during Engine Starting -
75-32-00-810-839-A
[PW11]
[8]
LPC (2.5) Bleed Valve - LVDT Electrical Failure Channel A -
75-32-00-810-840-A
[PW11]
[8]
LPC (2.5) Bleed Valve - Torque Motor Electrical Failure Channel A -
75-32-00-810-841-A
[PW11]
[8]
HPC Bleed Valve Failed Open (not during starting) -
75-32-00-810-844-A
[PW11]
[8]
Active HPC Bleed Valve Failed Open (not during Start) -
75-32-00-810-845-A
[PW11]
[8]
Active HPC Bleed Valve Failed Closed (during Start) -
75-32-00-810-846-A
[PW11]
[8]
LPC (2.5) Bleed Valve Actuator Position Error - Trach Check Channel A -
75-32-00-810-847-A
[PW11]
[8]
LPC (2.5) Bleed Valve Actuator Position Error - Trach Check Channel B -
75-32-00-810-848-A
[PW11]
[8]
Active HPC Bleed Valve Solenoid Wraparound Failure Channel A -
75-32-00-810-849-A
[PW11]
[8]
Active HPC Bleed Valve Solenoid Wraparound Failure Channel B -
75-32-00-810-850-A
[PW11]
[8]
Active HPC Bleed Valve Pressure Signal Failure Channel A -
75-32-00-810-851-A
[PW11]
[8]
Active HPC Bleed Valve Pressure Signal Failure Channel B -
75-32-00-810-852-A
[PW11]
[8]
Active HPC Bleed Valve Pressure Disagreement Failure -
75-32-00-810-865-A
[PW11]
[8]
LPC (2.5) Bleed Valve - LVDT Electrical Failure on Channel A and B -
75-32-00-810-866-A
[PW11]
[8]
LPC (2.5) Bleed Valve Actuator Positon Error - Track Check on Channel A and B -
75-32-00-810-867-A
[PW11]
[8]
LPC (2.5) Bleed Valve - TM Electrical Failure on Channel A and B -
75-32-00-810-868-A
[PW11]
[8]
LPC SVA Position Error - Track Check on Channel A and B -
75-32-00-810-869-A
[PW11]
[8]
Active HPC Bleed Valve Solenoid Wraparound Failure on Channel A and B -
75-32-00-810-870-A
[PW11]
[8]
HPC Bleed Valve Pressure Signal Failure on Channel A and B -
75-32-00-810-871-A
[PW11]
[8]
Active HPC Bleed Valve Pressure Signal Failure on Channel A and B
-
75-32-00-810-831-A
[PW11]
[8]
- PB.201 CONF:[21] LOW PRESSURE COMPRESSOR (LPC) (2.5) BLEED VALVE ACTUATOR - FAULT ISOLATION PROCEDURES
-
75-32-01-810-801-A
[PW11]
[8]
LPC (2.5) Bleed Valve - LVDT Electrical Failure Channel B -
75-32-01-810-802-A
[PW11]
[8]
LPC (2.5) Bleed Valve - LVDT Signal Disagreement -
75-32-01-810-803-A
[PW11]
[8]
LPC (2.5) Bleed Valve - Torque Motor Electrical Failure Channel B
-
75-32-01-810-801-A
[PW11]
[8]