W DOC AIRBUS | MMEL ITEMS A320F

Probe Heat Computer (PHC)


30-31-01Probe Heat Computer (PHC)
Applicable to: -
30-31-01-A Associated probe heating operative
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
32No
(o)(m)
One may be inoperative provided that the associated probe heating is checked operative before each flight.

30-31-01-B F/O PHC inoperative
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
32No
(o)(m)
The F/O PHC may be inoperative provided that the ADRs, heaters and failure alerts associated with the operative computers are checked operative every day.

30-31-01-C STBY PHC inoperative
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
32No
(o)(m)
The STBY PHC may be inoperative provided that:

1)
The ADRs, heaters and failure alerts associated with the operative computers are checked operative every day, and

2)
The aircraft is not operated in visible moisture or in known or forecast icing conditions, and

3)
The OAT at the departure airport is above 5 °C when the taxiway or the runway are contaminated with water or slush.