Probe Heat Computer (PHC)
| 30-31-01 | Probe Heat Computer (PHC) |
|---|
Applicable to: -
30-31-01-A Associated probe heating operative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 3 | 2 | No |
(o)(m)
One may be inoperative provided that
the associated probe heating is checked operative before each flight.
+ Reference
30-31-01-B F/O PHC inoperative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 3 | 2 | No |
(o)(m)
The F/O PHC may
be inoperative provided that the ADRs, heaters and failure
alerts associated with the operative computers are checked operative
every day.
30-31-01-C STBY PHC inoperative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 3 | 2 | No |
(o)(m)
1)
2)
3)
The STBY PHC may
be inoperative provided that:
1)
The ADRs, heaters and failure
alerts associated with the operative computers are checked operative
every day, and
2)
The aircraft is not operated in visible
moisture or in known or forecast icing conditions, and
3)
The OAT at the departure airport is above 5 °C when the taxiway or the runway are contaminated
with water or slush.