LGCIU 2 Nose L/G Shock Absorber Proximity Detector
| 32-32-04 | LGCIU 2 Nose L/G Shock Absorber Proximity Detector |
|---|
Applicable to: -
32-32-04-A Other proximity detectors operative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| A | 1 | 0 | No |
(o)(m)
1)
2)
May be inoperative for 7 flights provided
that:
1)
The other proximity detectors are operative,
and
2)
The origin of the failure is checked
to be electrical.
32-32-04-B LGCIU 2 considered inoperative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| A | 1 | 0 | No |
May be inoperative for 7
flights provided that the LGCIU 2 is considered inoperative.
| 32-32-04 | LGCIU 2 Nose L/G Shock Absorber Proximity Detector |
|---|
Applicable to: -
32-32-04-A Other proximity detectors operative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| A | 1 | 0 | No |
(o)(m)
1)
2)
3)
May be inoperative for 7 flights provided that:
1)
The other proximity detectors are operative, and
2)
The origin of the failure is checked to be electrical, and
3)
The OAT is below ISA+ 35 °C.
32-32-04-B LGCIU 2 considered inoperative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| A | 1 | 0 | No |