W DOC AIRBUS | MMEL OPS PROC

LGCIU 2 Nose L/G Shock Absorber Proximity Detector


32-32-04ALGCIU 2 Nose L/G Shock Absorber Proximity Detector
Applicable to: -
- General Information
SYSTEMS
CONSEQUENCES
PROCEDURES
PITOTS(on ground)
The STBY pitot is set to the high heating level when the EXT PWR pb-sw is set to OFF.
If displayed, disregard the ANTI ICE CAPT(F/O) PITOT alert on the EWD when EXT PWR pb-sw is set to OFF.
Keep the EXT PWR pb-sw set to ON until the engine start.
HYD (on ground)
The PTU runs after the first engine start until the second engine is started.
ENG 2(on ground)
The minimum idle is inoperative when slats/flaps are extended.
ECAM(in flight and on ground)