Installation of the Lower Starter Duct [CFMB]


TASK 80-13-42-400-041-A
Installation of the Lower Starter Duct


FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
HAMMER - FIBER
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 70 and 50 lbf.in (0.79 and 0.57 m.daN ) T
No specific
Torque wrench: range to between 80 and 70 lbf.in (0.90 and 0.79 m.daN ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.CP8001)
lockwire 0.032 in. (0.8 mm) dia.
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-040-B
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-B
Closing of the Fan Cowl Doors
3. Job Set-up
Subtask 80-13-42-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
WARNING: IF IT IS NECESSARY TO ENERGIZE THE AIRCRAFT FOR A MAINTENANCE WORK WHILE YOU DO THIS MAINTENANCE PROCEDURE, MAKE SURE THAT ONLY EXTERNAL POWER IS USED. THE USE OF APU OR ENGINE POWER CAN CAUSE PRESSURIZED AIR LEAKAGE IN THE PNEUMATIC SYSTEM, AND INJURY CAN OCCUR.
   (1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
   (2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
   (3) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position.
   (4) On the AIR COND panel 30VU:
  • make sure that the APU BLEED pushbutton switch is released (ON legend is off),
  • make sure that a WARNING NOTICE(S) is in position to tell persons not to operate the pneumatic system.
   (5) On the HP ground connector:
  • make sure that a WARNING NOTICE(S) is in position to tell persons not to pressurize the pneumatic system.
Subtask 80-13-42-860-050-B ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
WARNING: IF IT IS NECESSARY TO ENERGIZE THE AIRCRAFT FOR A MAINTENANCE WORK WHILE YOU DO THIS MAINTENANCE PROCEDURE, MAKE SURE THAT ONLY EXTERNAL POWER IS USED. THE USE OF APU OR ENGINE POWER CAN CAUSE PRESSURIZED AIR LEAKAGE IN THE PNEUMATIC SYSTEM, AND INJURY CAN OCCUR.
   (1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
   (2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
   (3) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position.
   (4) On the AIR COND panel 30VU:
  • make sure that the APU BLEED pushbutton switch is released (OFF legend is on),
  • make sure that a WARNING NOTICE(S) is in position to tell persons not to operate the pneumatic system.
   (5) On the HP ground connector:
  • make sure that a WARNING NOTICE(S) is in position to tell persons not to pressurize the pneumatic system.
Subtask 80-13-42-010-051-A ** ON A/C NOT FOR ALL
B. Make sure that the fan cowl doors are open: (Ref. AMM TASK 71-13-00-010-040)
   (1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
   (2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
4. Procedure
Subtask 80-13-42-420-050-A ** ON A/C NOT FOR ALL
A. Install the lower starter duct.
F Lower Starter Duct ** ON A/C NOT FOR ALL
CAUTION: MAKE SURE THAT THE V-CLAMP ATTACHMENTS CAN NOT TOUCH ENGINE COMPONENTS OR STRUCTURE, TO PREVENT DAMAGE.
CAUTION: DURING INSTALLATION, ADJUST THE ORIENTATION OF THE LOWER DUCT. MAKE SURE THAT THE PS3 LINE DOES NOT TOUCH THE LOWER DUCT OR OTHER PARTS IN THIS AREA. IF IT DOES, CHAFING OF THE PS3 HOSE CAN OCCUR.
   (1) Remove the blanking plugs from the starter, the starter valve, and the two ends of the lower starter duct.
   (2) Put the lower starter duct (25) in position between the starter and the starter valve. Install the couplings (5). Tighten the couplings sufficiently to attach and hold the duct.
   (3) Put the links (30) in position on the two sides of the duct. Install the bolts (10), the washers (15), and the nuts (20).
Make sure that the washers are installed with the countersink against the bolt heads.
   (4) Adjust the links (30), as required to avoid a preload of the duct and the links.
   (5) TORQUE the nuts (20) to between 70 and 50 lbf.in (0.79 and 0.57 m.daN ) T.
   (6) Lock the links with CP8001lockwire 0.032 in. (0.8 mm) dia..
   (7) TORQUE the nuts on the couplings (5), as follows:
     (a) TORQUE the coupling nuts to between 80 and 70 lbf.in (0.90 and 0.79 m.daN )
T.
     (b) Lightly hit the perimeter of the coupling with a HAMMER - FIBER then torque the coupling nut again.
     (c) Do the torque procedure two times, then torque the coupling nut again.
5. Close-up