W DOC AIRBUS | AMM A320F

Removal of the Lower Starter Duct [CFMB]


TASK 80-13-42-000-041-A
Removal of the Lower Starter Duct


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
PLUG - BLANKING
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-040-B
Opening of the Fan Cowl Doors
3. Job Set-up
Subtask 80-13-42-941-050-A ** ON A/C NOT FOR ALL
A. Safety Precautions
WARNING: IF IT IS NECESSARY TO ENERGIZE THE AIRCRAFT FOR A MAINTENANCE WORK WHILE YOU DO THIS MAINTENANCE PROCEDURE, MAKE SURE THAT ONLY EXTERNAL POWER IS USED. THE USE OF APU OR ENGINE POWER CAN CAUSE PRESSURIZED AIR LEAKAGE IN THE PNEUMATIC SYSTEM, AND INJURY CAN OCCUR.
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
   (4) On the AIR COND panel 30VU:
  • make sure that the APU BLEED pushbutton switch is released (ON legend is off),
  • put a WARNING NOTICE(S) to tell persons not to operate the pneumatic system.
   (5) On the HP ground connector:
  • put a WARNING NOTICE(S) to tell persons not to pressurize the pneumatic system.
Subtask 80-13-42-941-050-B ** ON A/C NOT FOR ALL
A. Safety Precautions
WARNING: IF IT IS NECESSARY TO ENERGIZE THE AIRCRAFT FOR A MAINTENANCE WORK WHILE YOU DO THIS MAINTENANCE PROCEDURE, MAKE SURE THAT ONLY EXTERNAL POWER IS USED. THE USE OF APU OR ENGINE POWER CAN CAUSE PRESSURIZED AIR LEAKAGE IN THE PNEUMATIC SYSTEM, AND INJURY CAN OCCUR.
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
   (4) On the AIR COND panel 30VU:
  • make sure that the APU BLEED pushbutton switch is released (OFF legend is on),
  • put a WARNING NOTICE(S) to tell persons not to operate the pneumatic system.
   (5) On the HP ground connector:
  • put a WARNING NOTICE(S) to tell persons not to pressurize the pneumatic system.
Subtask 80-13-42-010-050-A ** ON A/C NOT FOR ALL
B. Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
   (1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
   (2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
4. Procedure
Subtask 80-13-42-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the lower starter duct.
F Lower Starter Duct ** ON A/C NOT FOR ALL
   (1) Remove the coupling (5) that attaches the starter duct (25) to the starter valve.
   (2) Remove the coupling (5) that attaches the starter duct (25) to the starter.
   (3) Cut the lockwire and remove the bolts (10), the washers (15), and the nuts (20) from the links (30) on the two sides of the duct.
   (4) Remove the lower starter duct (25) from the engine.
   (5) Install PLUG - BLANKING on the opening of the starter, the opening of the starter valve, and the two ends of the lower starter duct (25).
[Rev.10 from 2021] 2026.04.01 03:44:29 UTC