Check of the Starter Valve Manual Handle Position after Engine Start [CFMB]
TASK 80-11-00-040-044-A
Check of the Starter Valve Manual Handle Position after Engine Start
1. Reason for the Job
MMEL 80-07-01A
START VALVE POSITION INDICATION ON THE ENGINE SD PAGE
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 80-11-00-010-050-A ** ON A/C NOT FOR ALL
Subtask 80-11-00-210-050-A ** ON A/C NOT FOR ALL
Subtask 80-11-00-410-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 13:15:16 UTC
Check of the Starter Valve Manual Handle Position after Engine Start
1. Reason for the Job
MMEL 80-07-01A
START VALVE POSITION INDICATION ON THE ENGINE SD PAGE
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 438CR | |
| FOR [1000EM2] (ENGINE-2) | |
| 448CR | |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 80-11-00-010-050-A ** ON A/C NOT FOR ALL
A. Open the access door on fan cowl :
(1) FOR [1000EM1] (ENGINE-1)
438CR
(2) FOR [1000EM2] (ENGINE-2)
448CR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
438CR
(2) FOR [1000EM2] (ENGINE-2)
448CR
Subtask 80-11-00-210-050-A ** ON A/C NOT FOR ALL
A. After engine start cycle check on starter valve that the manual handle is in closed position.
5. Close-upSubtask 80-11-00-410-050-A ** ON A/C NOT FOR ALL
A. Close the access door on fan cowl
(1) FOR [1000EM1] (ENGINE-1)
438CR
(2) FOR [1000EM2] (ENGINE-2)
448CR
Subtask 80-11-00-941-050-A ** ON A/C NOT FOR ALL (1) FOR [1000EM1] (ENGINE-1)
438CR
(2) FOR [1000EM2] (ENGINE-2)
448CR
B. Safety Precautions
(1) Tell the crew to make an entry in the log book.
(1) Tell the crew to make an entry in the log book.
Starter Valve Access Panel