Test of the Oil Temperature Sensor [CFMB]
TASK 79-31-40-700-001-A
Test of the Oil Temperature Sensor
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 79-31-40-941-053-A ** ON A/C NOT FOR ALL
Subtask 79-31-40-760-050-A ** ON A/C NOT FOR ALL
Subtask 79-31-40-410-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:39:33 UTC
Test of the Oil Temperature Sensor
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | MULTIMETER - STANDARD |
| No specific | AR | PLIERS - CONNECTOR, JAW, SOFT |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
| TASK 79-32-15-000-042-A | Removal of the Oil Temperature Sensor (IDG Cooling System Control Sensor) |
| TASK 79-32-15-400-042-A | Installation of the Oil Temperature Sensor (IDG Cooling System Control Sensor) |
Subtask 79-31-40-941-053-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 79-31-40-010-054-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
Subtask 79-31-40-760-050-A ** ON A/C NOT FOR ALL
A. Electrical Test of the Oil Temperature Sensor.
(1) Disconnect the connector from the oil temperature sensor. Use PLIERS - CONNECTOR, JAW, SOFT only if necessary.
(2) Check the resistance values as follows. If they are different from the values given, replace the oil temperature sensor (Ref. AMM TASK 79-32-15-000-042) and (Ref. AMM TASK 79-32-15-400-042).
(a) Measure the resistance of each probe with a MULTIMETER - STANDARD. The resistance value must be between 200 and 278 Ohms, at ambient temperature.
(b) Measure the insulation resistance of each probe. The nominal value must be equal to or higher than 10 Megohms.
(3) Connect the connector to the oil temperature sensor. Use PLIERS - CONNECTOR, JAW, SOFT only if necessary.
5. Close-up(1) Disconnect the connector from the oil temperature sensor. Use PLIERS - CONNECTOR, JAW, SOFT only if necessary.
(2) Check the resistance values as follows. If they are different from the values given, replace the oil temperature sensor (Ref. AMM TASK 79-32-15-000-042) and (Ref. AMM TASK 79-32-15-400-042).
(a) Measure the resistance of each probe with a MULTIMETER - STANDARD. The resistance value must be between 200 and 278 Ohms, at ambient temperature.
(b) Measure the insulation resistance of each probe. The nominal value must be equal to or higher than 10 Megohms.
(3) Connect the connector to the oil temperature sensor. Use PLIERS - CONNECTOR, JAW, SOFT only if necessary.
Subtask 79-31-40-410-053-A ** ON A/C NOT FOR ALL