Resetting of the Visual Indicator [CFMB]
TASK 79-21-30-440-001-A
Resetting of the Visual Indicator
1. Reason for the Job
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 79-21-30-941-050-A ** ON A/C NOT FOR ALL
Subtask 79-21-30-440-050-A ** ON A/C NOT FOR ALL
Subtask 79-21-30-410-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:39:19 UTC
Resetting of the Visual Indicator
1. Reason for the Job
NOTE: This deactivation task is not related to an AFM-CDL/MMEL item.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.CP8001) | lockwire 0.032 in. (0.8 mm) dia. |
| (Material No.CP8002) | lockwire 0.032 in. (0.8 mm) dia |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
Subtask 79-21-30-941-050-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 79-21-30-865-050-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 79-21-30-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 1000EM1 (ENGINE1) | |||
| 121VU | ENGINE/ENG1/OIL/CHIP/DET | 4EN1 | N38 |
| FOR FIN: 1000EM2 (ENGINE2) | |||
| 121VU | ENGINE/ENG2/OIL/CHIP/DET | 4EN2 | N43 |
C. Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
Subtask 79-21-30-440-050-A ** ON A/C NOT FOR ALL
A. Resetting of the visual indicator
PRE SB CFM 79-0014
(1) Cut and remove the lockwire.
(2) Remove the cover assembly (20) from the visual indicator.
(3) Push the red pop-out type indicator (10) until it is kept by the magnet.
(4) Install the cover assembly (20) on the visual indicator. Tighten by hand.
(5) Safety the cover assembly (20) withCP8001 lockwire 0.032 in. (0.8 mm) dia. or CP8002 lockwire 0.032 in. (0.8 mm) dia .
END OF PRE SB CFM 79-0014
POST SB CFM 79-0014 or POST SB CFM 79-0023 or POST SB CFM 79-0036
Resetting of the Visual Indicator (POST SB CFM 79-0014 or POST SB CFM 79-0023 or POST SB CFM 79-0036) ** ON A/C NOT FOR ALL
(6) Push the protective cap (30).
END OF POST CFM 79-0014 or POST SB CFM 79-0023 or POST SB CFM 79-0036
5. Close-upPRE SB CFM 79-0014
(1) Cut and remove the lockwire.
(2) Remove the cover assembly (20) from the visual indicator.
(3) Push the red pop-out type indicator (10) until it is kept by the magnet.
(4) Install the cover assembly (20) on the visual indicator. Tighten by hand.
(5) Safety the cover assembly (20) with
END OF PRE SB CFM 79-0014
POST SB CFM 79-0014 or POST SB CFM 79-0023 or POST SB CFM 79-0036
Resetting of the Visual Indicator (POST SB CFM 79-0014 or POST SB CFM 79-0023 or POST SB CFM 79-0036) ** ON A/C NOT FOR ALL END OF POST CFM 79-0014 or POST SB CFM 79-0023 or POST SB CFM 79-0036
Subtask 79-21-30-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(3) Remove the WARNING NOTICE(S).
(4) Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
4EN1, 4EN2.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(3) Remove the WARNING NOTICE(S).
(4) Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
4EN1, 4EN2.