W DOC AIRBUS | AMM A320F

Inspection/Check of the Main Oil/Fuel Heat Exchanger [CFMB]


TASK 79-21-20-210-002-A
Inspection/Check of the Main Oil/Fuel Heat Exchanger


FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-040-B
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-B
Closing of the Fan Cowl Doors
TASK 79-21-20-000-002-A
Removal of the Main Oil/Fuel Heat Exchanger
TASK 79-21-20-400-002-A
Installation of the Main Oil/Fuel Heat Exchanger
3. Job Set-up
Subtask 79-21-20-941-052-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 79-21-20-010-054-A ** ON A/C NOT FOR ALL
B. Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
   (1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
   (2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
4. Procedure
Subtask 79-21-20-210-051-A ** ON A/C NOT FOR ALL
A. Visually inspect the main oil/fuel heat exchanger
INSPECT/CHECK
MAXIMUM SERVICEABLE LIMITS
REMARKS
1.All areas for :


A.Cracks
Not serviceable
Replace main oil/fuel heat exchanger (Ref. AMM TASK 79-21-20-000-002) and (Ref. AMM TASK 79-21-20-400-002)
2.External sealing faces for :


A.Dents, gouges, scratches
Not serviceable
Replace main oil/fuel heat exchanger (Ref. AMM TASK 79-21-20-000-002) and (Ref. AMM TASK 79-21-20-400-002)
5. Close-up
Subtask 79-21-20-410-053-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the fan cowl doors: (Ref. AMM TASK 71-13-00-410-040)
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (3) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 03:39:18 UTC