Reactivation of the Thrust Reverser System Non-Return Valve [IAE]
TASK 78-31-00-440-040-A
Reactivation of the Thrust Reverser System Non-Return Valve
1. Reason for the Job
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 78-31-00-860-067-A ** ON A/C NOT FOR ALL
Subtask 78-31-00-440-051-A ** ON A/C NOT FOR ALL
Subtask 78-31-00-410-055-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:27:27 UTC
Reactivation of the Thrust Reverser System Non-Return Valve
1. Reason for the Job
NOTE: This deactivation task is not related to an AFM-CDL/MMEL item
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.V02-147) | lockwire |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 413AL | |
| FOR [1000EM2] (ENGINE-2) | |
| 423AL | |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 78-31-00-860-067-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
(2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
(3) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position.
(4) Make sure that the access panel in the pylon is removed.
4. Procedure(1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
(2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
(3) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position.
(4) Make sure that the access panel in the pylon is removed.
Subtask 78-31-00-440-051-A ** ON A/C NOT FOR ALL
A. Put the thrust reverser system non-return valve in the normal position.
(1) Put the lever (2) of the valve (1) at 90 degrees to the longitudinal axis of the valve.
(2) Safety the lever in the normal position with the lockwire (Material No.V02-147) .
5. Close-up(1) Put the lever (2) of the valve (1) at 90 degrees to the longitudinal axis of the valve.
(2) Safety the lever in the normal position with the lockwire (Material No.V02-147) .
Subtask 78-31-00-410-055-A ** ON A/C NOT FOR ALL
Thrust Reverser System Non-Return Valve