W DOC AIRBUS | AMM A320F

Reactivation of the Thrust Reverser System after Translating Sleeve Stop Device Installation [CFML]


TASK 78-30-00-440-813-A
Reactivation of the Thrust Reverser System after Translating Sleeve Stop Device Installation


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
ZONE: 400
1. Reason for the Job
CDL 78-25
Thrust Reverser Translating Sleeve Stop Device
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
400
POWER PLANT, NACELLES AND PYLONS
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 78-30-00-440-808-A
Reactivation of the Thrust Reverser System after Flight
3. Job Set-up
Subtask 78-30-00-941-101-A
A. Not Applicable
4. Procedure
Subtask 78-30-00-440-080-A
A. Do as follow:
   (1) Do the reactivation of the thrust reverser for flight (Ref. AMM TASK 78-30-00-440-808).