W DOC AIRBUS | AMM A320F

General Visual Inspection of the Throttle Control System [IAE]


TASK 76-11-00-210-040-A
General Visual Inspection of the Throttle Control System


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
LIGHT SOURCE - INSPECTION
No specific
AR
MIRROR - INSPECTION
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
811
 C. Referenced Information
REFERENCE
DESIGNATION
3. Job Set-up
Subtask 76-11-00-941-050-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Make sure that the throttle control levers are set to idle (0 degrees TLA).
   (2) Put a WARNING NOTICE(S) in the cockpit to tell persons not to move:
  • the throttle control levers
  • the slat and flaps control levers.
   (3) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the forward avionics compartment.
Subtask 76-11-00-010-050-A ** ON A/C NOT FOR ALL
B. Open the access door 811.
4. Procedure
Subtask 76-11-00-210-050-A ** ON A/C NOT FOR ALL
A. Inspection of Trottle Control System.
   (1) Visually examine the throttle control unit (4).
     (a) Make sure that the mount nuts which attach the throttle control unit (4) to its support are not loose.
     (b) Make sure that the four electrical connectors (5) are tighten.
   (2) Visually examine the lower rods (3).
     (a) Make sure that the upper and lower attachments of the rods are lockwired.
     (b) Make sure that the rods can move freely on their bearings.
   (3) Visually examine the upper rods (2).
     (a) Repeat the same inspection as for the lower rods. For the upper attachment of the rods, use an LIGHT SOURCE - INSPECTION and an MIRROR - INSPECTION.
   (4) Visually examine the bellcrank (6) of the throttle control lever.
     (a) Make sure that there is no foreign object in the system and in its area.
   (5) Visually examine the throttle control levers (1) in the cockpit for good condition.
     (a) Make sure that there are no unwanted object which can prevent the full travel of the levers.
5. Close-up
Subtask 76-11-00-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the access door 811.
   (3) Remove the access platform(s).
   (4) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 03:15:43 UTC