Removal of the High Pressure Compressor (HPC) Stage 7 Solenoid Valve [IAE]
TASK 75-32-51-000-010-A
Removal of the High Pressure Compressor (HPC) Stage 7 Solenoid Valve
The HPC stage 7 solenoid valve 4020KS1 controls the HPC bleed valve at the top right position.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 75-32-51-941-050-A ** ON A/C NOT FOR ALL
Subtask 75-32-51-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:12:20 UTC
Removal of the High Pressure Compressor (HPC) Stage 7 Solenoid Valve
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
ZONE: 400
FIN: 4020KS1 ** ON A/C NOT FOR ALL
FIN: 4020KS2 ** ON A/C NOT FOR ALL
FIN: 4020KS3 ** ON A/C NOT FOR ALL
1. Reason for the JobFIN: 4020KS1 ** ON A/C NOT FOR ALL
FIN: 4020KS2 ** ON A/C NOT FOR ALL
FIN: 4020KS3 ** ON A/C NOT FOR ALL
The HPC stage 7 solenoid valve 4020KS1 controls the HPC bleed valve at the top right position.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | COVER - PROTECTION |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-010-A | Opening of the Fan Cowls 437AL(447AL),438AR(448AR) |
Subtask 75-32-51-941-050-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 75-32-51-010-050-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
4. Procedure(1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
Subtask 75-32-51-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the HPC stage 7 solenoid valve
(1) Disconnect the HP3 air tubes
(a) Cut and discard the wire and disconnect the HP3 air outlet tube (2) from the solenoid valve.
(b) Cut and discard the wire and disconnect the HP3 air inlet tube (1) from the solenoid valve.
(2) Disconnect the electrical connector (6) from the solenoid valve
(3) Remove the HPC stage 7 solenoid valve
(a) Remove the bolts (4) and the washers (5) which attach the solenoid valve to the mounting bracket (3).
(b) Remove the solenoid valve.
Subtask 75-32-51-620-050-A ** ON A/C NOT FOR ALL (1) Disconnect the HP3 air tubes
(a) Cut and discard the wire and disconnect the HP3 air outlet tube (2) from the solenoid valve.
(b) Cut and discard the wire and disconnect the HP3 air inlet tube (1) from the solenoid valve.
(2) Disconnect the electrical connector (6) from the solenoid valve
(3) Remove the HPC stage 7 solenoid valve
(a) Remove the bolts (4) and the washers (5) which attach the solenoid valve to the mounting bracket (3).
(b) Remove the solenoid valve.
B. Put the applicable COVER - PROTECTION on all of the openings.