Installation of the ECU Air Cooling Tube [CFMB]
TASK 75-24-49-400-040-A
Installation of the ECU Air Cooling Tube
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 75-24-49-860-050-A ** ON A/C NOT FOR ALL
Subtask 75-24-49-420-050-A ** ON A/C NOT FOR ALL
Subtask 75-24-49-410-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 13:08:29 UTC
Installation of the ECU Air Cooling Tube
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
Subtask 75-24-49-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
(2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
(3) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position.
Subtask 75-24-49-010-052-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
(2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
(3) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position.
B. Make sure that the fan cowl doors are open: (Ref. AMM TASK 71-13-00-010-040)
(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
Subtask 75-24-49-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the ECU air cooling tube.
(1) Remove the protective covers from the ECU and the ECU cooling duct.
(2) Install the clamps (5) on each end of the ECU air cooling tube (10).
(3) Compress the ECU air cooling tube (10) and install it on the ECU and the ECU cooling duct.
(4) Move the clamps (5) into position at each end of the ECU air cooling tube (10). Tighten the clamps.
5. Close-up(1) Remove the protective covers from the ECU and the ECU cooling duct.
(2) Install the clamps (5) on each end of the ECU air cooling tube (10).
(3) Compress the ECU air cooling tube (10) and install it on the ECU and the ECU cooling duct.
(4) Move the clamps (5) into position at each end of the ECU air cooling tube (10). Tighten the clamps.
Subtask 75-24-49-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors: (Ref. AMM TASK 71-13-00-410-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors: (Ref. AMM TASK 71-13-00-410-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
ECU Air Cooling Tube