W DOC AIRBUS | AMM A320F

Leak Check of the Pb Sense Line [IAE]


TASK 73-22-49-790-010-A
Leak Check of the Pb Sense Line


1. Reason for the Job
This procedure outlines how to check for leaks in the Pb sense lines
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
NITROGEN COMPRESSED SOURCE 5 BAR (72.5 PSI) - (DRY)
No specific
1
PLUG - BLANKING (AS15829 TYPE)
No specific
1
PLUG - BLANKING, PRESSURE
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 44 and 36 lbf.in (0.50 and 0.41 m.daN ) T
No specific
Torque wrench: range to between 45 and 36 lbf.in (0.51 and 0.41 m.daN ) T
No specific
Torque wrench: range to between 150 and 142 lbf.in (1.70 and 1.60 m.daN ) T
No specific
Torque wrench: range to between 177 and 159 lbf.in (2.00 and 1.80 m.daN ) T
No specific
Torque wrench: range to between 310 and 283 lbf.in (3.50 and 3.20 m.daN ) T
IAE1R19786
1
CONNECTOR
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.V02-126)
lockwire
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 70-23-11-911-013-A
General Torque Tightening Techniques
TASK 71-13-00-010-010-A
Opening of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 71-13-00-410-010-A
Closing of the Fan Cowls 437AL(447AL),438AR(448AR)
3. Job Set-up
Subtask 73-22-49-941-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize FADEC 1(2).
Subtask 73-22-49-010-051-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
4. Procedure
Subtask 73-22-49-020-053-A ** ON A/C NOT FOR ALL
A. Remove the Pb sense line pipe
F PB Sense Line ** ON A/C NOT FOR ALL
   (1) Remove and discard the lockwire from the connectors.
   (2) Disconnect the connector nut (1) from the P3/T3 sensor.
   (3) Disconnect the connector nut (3) from the tube (2).
For Pre SB 75-0081
   (4) Remove the bolt (7) and the washer (6) from the clip point 5433.
For Post SB 75-0081
   (5) Remove the nut (12), the bolt (8) and the spacer (10) from the clip point 6108.
End of SB 75-0081.
   (6) Remove the nut (14), bolt (19), washer (18) and spacer (15) from the clip point 6066.
   (7) Remove the pipe (2).
Subtask 73-22-49-020-057-A ** ON A/C NOT FOR ALL
B. Disconnect the Tube at the Electronic Engine Control (EEC)
   (1) Remove the lockwire from the tube nut.
   (2) Disconnect the tube at the EEC unit.
   (3) Put a PLUG - BLANKING, PRESSURE in the tube to prevent air leakage. No air leakage is permitted.
Subtask 73-22-49-420-052-A ** ON A/C NOT FOR ALL
C. Preparation for the pressure test
   (1) Install the IAE1R19786 CONNECTOR to the pipe (4).
   (2) Connect the nitrogen supply to the connector.

PRE SBE 73-0198

   (3) Blank off the vented traps.
     (a) Blank off the vented traps using clips and bolts as shown in figure.
F Water Trap Blanking ** ON A/C NOT FOR ALL
     (b) TORQUE the nut (6) to between 44 and 36 lbf.in (0.50 and 0.41 m.daN ) T.

END OF PRE SBE 73-0198

POST SBE 73-0198

   (4) Install the blanking plug.
     (a) Remove the vented plug assembly and install the PLUG - BLANKING (AS15829 TYPE).
     (b) TORQUE the blanking plug to between 310 and 283 lbf.in (3.50 and 3.20 m.daN )
T.

END OF POST SBE 73-0198

   (5) Coat the sense line joints, including the flexible tube that connects to the EEC, with snoop leak detection fluid.
NOTE: Make sure that the upper flexible section of the sense line is coated on the flexible portion and the unions.
Subtask 73-22-49-720-050-A ** ON A/C NOT FOR ALL
D. Test
CAUTION: DO NOT BLOW AIR OR NITROGEN GAS THROUGH THE SENSING LINES TO THE ELECTRONIC ENGINE CONTROL UNIT (EEC). UNWANTED MATERIALS CAN CAUSE CONTAMINATION AND DAMAGE TO THE EEC.
   (1) Carefully open the regulator valve of the NITROGEN COMPRESSED SOURCE 5 BAR (72.5 PSI) - (DRY) and gradually increase the pressure to 75 psi and check for leaks.
   (2) Continue to pressurize the sense lines for two minutes.
NOTE: If necessary, re-apply snoop leak detection fluid to confirm a leak.
   (3) If a leak is detected, identify the leaking joint/s. If possible photograph the joint and the tube clipping arrangement both sides of the joint.
   (4) Release the pressure from the sense line.
   (5) Check the security of the unions or any leaking joints. Torque the connector to the recommended range (
Ref. AMM TASK 70-23-11-911-013).
   (6) If connectors are found under-tightened, torque to the recommended range and repeat the leak check.
   (7) If a leak is found in the flexible line or on a rigid tube, replace the defective parts and repeat the leak check.
   (8) If a joint continues to leak, replace the tubes both sides of the leaking joint and inform IAE Technical Services stating the location.
NOTE: If replacement parts are not available before the aircraft returns to service, arrange for their replacement at the next convenient point when spare parts become available.
   (9) Clean the snoop leak detection fluid from the tubes.
   (10) Remove the nitrogen supply and the connector IAE1R19786 from the tube (4).

PRE SBE 73-0198

   (11) Loosen the nut (6) and remove the bolts and the blanking clips from the vented traps.
F Water Trap Blanking ** ON A/C NOT FOR ALL

END OF PRE SBE 73-0198

POST SBE 73-0198

   (12) Remove the blanking plug (AS15829) and install the vented plug assembly. TORQUE the vented plug assembly to between 310 and 283 lbf.in (3.50 and 3.20 m.daN ) T.

END OF POST SBE 73-0198

Subtask 73-22-49-420-053-A ** ON A/C NOT FOR ALL Subtask 73-22-49-420-056-A ** ON A/C NOT FOR ALL 5. Close-up
Subtask 73-22-49-410-051-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010) :
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (3) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 03:01:09 UTC