Installation of the T12 Temperature Sensor [CFMB]
TASK 73-21-40-400-001-A
Installation of the T12 Temperature Sensor
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 73-21-40-860-050-A ** ON A/C NOT FOR ALL
Subtask 73-21-40-420-050-A ** ON A/C NOT FOR ALL
Subtask 73-21-40-410-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:58:31 UTC
Installation of the T12 Temperature Sensor
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
| TASK 73-29-00-710-040-B-02 | Operational Test of the FADEC on the Ground (with Engine Non motoring) |
Subtask 73-21-40-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
(2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
(3) Make sure that the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE is in position.
(4) Make sure that MAT - PROTECTIVE is in position.
Subtask 73-21-40-010-051-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
(2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
(3) Make sure that the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE is in position.
(4) Make sure that MAT - PROTECTIVE is in position.
B. Make sure that the fan cowl doors are open: (Ref. AMM TASK 71-13-00-010-040)
(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
Subtask 73-21-40-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the T12 temperature sensor.
(1) Install the T12 sensor on the fan frame boss.
.
(3) Remove the blanking cap from the electrical connectors and the blanking plug from the sensor housing.
(4) Install the electrical connectors on the sensor housing .
(5) Install the housing strip on the sensor housing.
(6) Install the nut and washer which secure the bonding strip to the sensor housing. TORQUE the nut to between 42 and 38 lbf.in (0.4746 and 0.4294 m.daN )
.
Subtask 73-21-40-869-052-A ** ON A/C NOT FOR ALL (1) Install the T12 sensor on the fan frame boss.
NOTE: Post CFM SB 72-0763 T12 sensor must be secure to the fan frame boss using Post CFM SB 72-0763 bolts.
(2) Secure the T12 sensor to the fan frame boss using 4 bolts and washers. TORQUE the bolts to between 110.62 and 97.35 lbf.in (1.25 and 1.10 m.daN )
.(3) Remove the blanking cap from the electrical connectors and the blanking plug from the sensor housing.
(4) Install the electrical connectors on the sensor housing .
(5) Install the housing strip on the sensor housing.
(6) Install the nut and washer which secure the bonding strip to the sensor housing. TORQUE the nut to between 42 and 38 lbf.in (0.4746 and 0.4294 m.daN )
. B. Make sure that the work area is clean and clear of tools and other items.
Subtask 73-21-40-942-051-A ** ON A/C NOT FOR ALL C. Put the aircraft back to its initial configuration.
(1) Remove the MAT - PROTECTIVE from the inlet cowl.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
Subtask 73-21-40-710-050-A ** ON A/C NOT FOR ALL 5. Close-up(1) Remove the MAT - PROTECTIVE from the inlet cowl.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
Subtask 73-21-40-410-050-A ** ON A/C NOT FOR ALL
T12 Sensor