Installation of the Adapter Housing [IAE]
TASK 73-12-41-400-011-B
Installation of the Adapter Housing
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Expendable Parts
D. Referenced Information
3. Job Set-up
Subtask 73-12-41-860-053-A ** ON A/C NOT FOR ALL
Subtask 73-12-41-420-061-A ** ON A/C NOT FOR ALL
Subtask 73-12-41-410-059-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:00:19 UTC
Installation of the Adapter Housing
FIN: 2001EM ** ON A/C NOT FOR ALL
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AL, 448AR | |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 226 | SEALING RING | AIPC 73-12-41-80-150 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 70-23-11-911-013-A | General Torque Tightening Techniques |
| TASK 70-23-13-911-010-A | Procedures for the Installation of Preformed Packings |
| TASK 71-00-00-710-012-B | Test No.3 : Idle Leak Check |
| TASK 71-00-00-710-046-B | Test No.2 : Wet Motor Leak Check |
| TASK 71-13-00-010-010-A | Opening of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-410-010-A | Closing of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 73-12-41-400-010-B | Installation of the Low Pressure (LP)/High Pressure (HP) Fuel Pump |
Subtask 73-12-41-860-053-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
(2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
Subtask 73-12-41-010-063-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
(2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
B. Make sure that the fan cowls are open (Ref. AMM TASK 71-13-00-010-010):
(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
Subtask 73-12-41-420-061-A ** ON A/C NOT FOR ALL
A. Installation of the adapter housing (227)
(1) Remove the applicable covers/caps/plugs from all of the openings.
(2) Install a new AIPC 73-12-41-80-150 SEALING RING (226) (226) on the adapter housing (227) (Ref. AMM TASK 70-23-13-911-010).
(3) Install the adapter housing (227) on the gearbox (225).
(4) Install the bracket (224), the two nuts (223), the four washers (221) and the four nuts (222).
(5) TORQUE the nuts (222) and (223) to between 220 and 180 lbf.in (2.49 and 2.03 m.daN )
(Ref. AMM TASK 70-23-11-911-013).
(6) Attach the clip (231) to the bracket (234) with the bolt (232) and the washer (233) at Detail AE.
(7) TORQUE the bolt (232) to between 45 and 36 lbf.in (0.51 and 0.41 m.daN )
(Ref. AMM TASK 70-23-11-911-013).
Subtask 73-12-41-410-058-A ** ON A/C NOT FOR ALL 5. Close-up(1) Remove the applicable covers/caps/plugs from all of the openings.
(2) Install a new AIPC 73-12-41-80-150 SEALING RING (226) (226) on the adapter housing (227) (Ref. AMM TASK 70-23-13-911-010).
(3) Install the adapter housing (227) on the gearbox (225).
(4) Install the bracket (224), the two nuts (223), the four washers (221) and the four nuts (222).
(5) TORQUE the nuts (222) and (223) to between 220 and 180 lbf.in (2.49 and 2.03 m.daN )
(Ref. AMM TASK 70-23-11-911-013). (6) Attach the clip (231) to the bracket (234) with the bolt (232) and the washer (233) at Detail AE.
(7) TORQUE the bolt (232) to between 45 and 36 lbf.in (0.51 and 0.41 m.daN )
(Ref. AMM TASK 70-23-11-911-013). Subtask 73-12-41-410-059-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
(3) FOR [1000EM1] (ENGINE-1)
437AL 438AL
(4) FOR [1000EM2] (ENGINE-2)
447AL 448AL
(5) Remove the WARNING NOTICE(S).
Subtask 73-12-41-790-053-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
(3) FOR [1000EM1] (ENGINE-1)
437AL 438AL
(4) FOR [1000EM2] (ENGINE-2)
447AL 448AL
(5) Remove the WARNING NOTICE(S).
B. Test Requirements
(1) Do an idle leak check (Ref. AMM TASK 71-00-00-710-012).
(1) Do an idle leak check (Ref. AMM TASK 71-00-00-710-012).
NOTE: A wet motor leak check (Ref. AMM TASK 71-00-00-710-046) may be used to check for leaks, but this must be followed by an idle leak check (Ref. AMM TASK 71-00-00-710-012).
Adapter Housing