W DOC AIRBUS | AMM A320F

Low Pressure Compressor (LPC) Integrally Bladed Rotor Borescope Blend Repair [PW11]


TASK 72-31-01-300-802-A
Low Pressure Compressor (LPC) Integrally Bladed Rotor Borescope Blend Repair


ZONE: 400
1. Reason for the Job
The critical nature of this special procedure means that any facility not authorized to accomplish this procedure either utilize a qualified vendor or contact IAE via the Pratt & Whitney global operations center before initiating the procedures contained within this SP. IAE is the sole source for qualification data in support of source demonstration programs. Any facility not authorized to perform the special procedure may contact IAE via the Pratt & Whitney global operations center to determine if a qualification program can be initiated at their facility.
The designation by IAE of an authorized vendor indicates that the vendor has demonstrated the necessary capability to enable it to carry out the procedure. However, IAE makes no warranties or representations concerning the qualifications or quality standards of the vendor to carry out the procedure and accepts no responsibility what so ever for any work that may be carried out by a vendor, other than when IAE is listed as the vendor. Authorized vendors do not act as agents or representatives of IAE or IAEs member companies.
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
400
POWER PLANT, NACELLES AND PYLONS
3. Job Set-up
Subtask 72-31-01-860-050-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Procedure
Subtask 72-31-01-320-050-A ** ON A/C NOT FOR ALL
A. Low Pressure Compressor (LPC) Integrally Bladed Rotor Borescope Blend Repair
CAUTION: EXCEPT FOR WORK OR SUPPLIES TO BE PERFORMED OR FURNISHED BY IAE LLC, IAE LLC DOES NOT ENDORSE THE WORK PERFORMED BY THE COMPANY OR COMPANIES IDENTIFIED HEREIN OR ANY OTHER COMPANY AND DOES NOT ACCEPT RESPONSIBILITY TO ANY DEGREE FOR THE SELECTION OF SUCH COMPANY OR COMPANIES FOR THE PERFORMANCE OF ANY WORK OR PROCUREMENT OF SUPPLIES.
CAUTION: BECAUSE THIS REPAIR IS CRITICAL, EACH FACILITY THAT INTENDS TO DO THIS REPAIR MUST CONTACT IAE LLC BEFORE THEY START THE REPAIR PROCEDURES.
   (1) This is a source demonstration repair. A source demonstration is necessary. Send acceptable parts to the approved source for this repair. Sources which are approved for this repair on this part are in the list that follows by source code number. Refer to the repair vendor list for the company names identified by these numbers.

No approved source

   (2) Repair facilities must show to IAE LLC that they can do this repair. IAE LLC may be contacted via the Pratt & Whitney Global Operations Center to determine the current list of qualified vendors, or to request a new facility demonstration program.

Pratt & Whitney
Manager, Joint Ventures, Partnerships and Licensing,
Fax 860-557-7197,
E-mail gppwlicng@pw.utc.com, or
Mail Stop 133-58,
400 Main Street
East Hartford, CT 06108
[Rev.10 from 2021] 2026.04.01 02:49:14 UTC