Repair of Fan Duct Panel [CFMB]
TASK 72-23-00-300-042-A
Repair of Fan Duct Panel
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Referenced Information
3. Job Set-up
Subtask 72-23-00-941-082-A ** ON A/C NOT FOR ALL
Subtask 72-23-00-410-086-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 12:59:50 UTC
Repair of Fan Duct Panel
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.CP5006) | austenite stainless steel wire - 321SS |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 72-23-00-000-027-A | Removal of the Fan Duct Panels |
| TASK 72-23-00-400-027-A | Installation of the Fan Duct Panels |
| SPM 703211230005 | |
| SPM 704111350009 | |
| SPM 704511310002 | |
Subtask 72-23-00-941-082-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 72-23-00-010-092-A ** ON A/C NOT FOR ALL 4. Procedure(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
NOTE: This repair procedure provides instruction for reconditioning cracked fan duct panels by weld buildup.
Subtask 72-23-00-310-052-A ** ON A/C NOT FOR ALL A. Stop the crack by drilling a 0.079 in. (2 mm) dia. hole at both ends.
(1) Weld up the crack under argon atmosphere, and using weld wire austenite stainless steel wire - 321SS (Material No.CP5006) . SPM 704511310002.
(2) Check the welded area SPM 703211230005.
(3) Flush the weld bead SPM 704111350009.
(4) Perform a fluorescent inspection of the weld bead SPM 703211230005.
5. Close-up(1) Weld up the crack under argon atmosphere, and using weld wire austenite stainless steel wire - 321SS (Material No.CP5006) . SPM 704511310002.
(2) Check the welded area SPM 703211230005.
(3) Flush the weld bead SPM 704111350009.
(4) Perform a fluorescent inspection of the weld bead SPM 703211230005.
Subtask 72-23-00-410-086-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Install the fan duct panel (Ref. AMM TASK 72-23-00-400-027).
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Remove the WARNING NOTICE(S).
(1) Install the fan duct panel (Ref. AMM TASK 72-23-00-400-027).
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Remove the WARNING NOTICE(S).
Fan Duct Panels