W DOC AIRBUS | AMM A320F

Repair of Fan Duct Panel [CFMB]


TASK 72-23-00-300-042-A
Repair of Fan Duct Panel


FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
WARNING NOTICE(S)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.CP5006)
austenite stainless steel wire - 321SS
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 72-23-00-000-027-A
Removal of the Fan Duct Panels
TASK 72-23-00-400-027-A
Installation of the Fan Duct Panels
SPM 703211230005
SPM 704111350009
SPM 704511310002
3. Job Set-up
Subtask 72-23-00-941-082-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 72-23-00-010-092-A ** ON A/C NOT FOR ALL
B. Remove the fan duct panel (Ref. AMM TASK 72-23-00-000-027).
4. Procedure
NOTE: This repair procedure provides instruction for reconditioning cracked fan duct panels by weld buildup.
Subtask 72-23-00-310-052-A ** ON A/C NOT FOR ALL
A. Stop the crack by drilling a 0.079 in. (2 mm) dia. hole at both ends.
   (1) Weld up the crack under argon atmosphere, and using weld wire austenite stainless steel wire - 321SS (Material No.CP5006) . SPM 704511310002.
   (2) Check the welded area SPM 703211230005.
   (3) Flush the weld bead SPM 704111350009.
   (4) Perform a fluorescent inspection of the weld bead SPM 703211230005.
5. Close-up
Subtask 72-23-00-410-086-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Install the fan duct panel (Ref. AMM TASK 72-23-00-400-027).
   (2) Make sure that the work area is clean and clear of tools and other items.
   (3) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 02:42:01 UTC