De-activation of the Frangible Drain Mast [CFMI]
TASK 71-71-42-040-044-A
De-activation of the Frangible Drain Mast
1. Reason for the Job
CDL 71-01
Frangible Drain Mast
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 71-71-42-941-056-A ** ON A/C NOT FOR ALL
Subtask 71-71-42-020-058-A ** ON A/C NOT FOR ALL Subtask 71-71-42-210-054-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:23:41 UTC
De-activation of the Frangible Drain Mast
1. Reason for the Job
CDL 71-01
Frangible Drain Mast
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-11-000-804-A | Removal of the Drain Mast Seal of the Fan Cowl Door |
| TASK 71-13-11-400-804-A | Installation of the Drain Mast Seal of the Fan Cowl Door |
| TASK 71-71-42-000-040-A | Removal of the Drain Mast |
Subtask 71-71-42-941-056-A ** ON A/C NOT FOR ALL
A. Not applicable.
4. ProcedureSubtask 71-71-42-020-058-A ** ON A/C NOT FOR ALL Subtask 71-71-42-210-054-A ** ON A/C NOT FOR ALL
B. Before each flight, without opening the fan cowl doors, do an inspection of the fan cowl drain mast seals for wear, damage, hole and tear deformation of the curved sections of the seal along lower edge of the fan cowl doors.
Subtask 71-71-42-960-050-A ** ON A/C NOT FOR ALL C. Replace worn or damaged parts (Ref. AMM TASK 71-13-11-000-804) and (Ref. AMM TASK 71-13-11-400-804).