Removal of the Hold Open Rod (HOR) Bracket Bolts [PW11]
TASK 71-13-86-000-802-A
Removal of the Hold Open Rod (HOR) Bracket Bolts
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 71-13-86-941-052-A ** ON A/C NOT FOR ALL
Subtask 71-13-86-020-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 12:57:21 UTC
Removal of the Hold Open Rod (HOR) Bracket Bolts
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING:
WEAR APPLICABLE PERSONAL PROTECTIVE EQUIPMENT (PPE) WHEN YOU DO THIS TASK. BEFORE YOU USE PPE, READ, UNDERSTAND AND OBEY ALL INSTRUCTIONS FOR ITS USE. THESE INSTRUCTIONS INCLUDE INSTRUCTIONS FROM THE MANUFACTURER, YOUR EMPLOYER AND GOVERNMENT REGULATIONS. YOU CAN GET INJURED IF YOU DO NOT USE PPE. GET INSTRUCTIONS FROM YOUR EMPLOYER ON WHICH PPE IS NECESSARY.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M(3 FT) |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-00-860-833-A | Procedure to Prevent Engine Motoring |
| TASK 71-13-00-010-805-A | Opening of the Fan Cowl Doors - Sling Method |
Subtask 71-13-86-941-052-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
Subtask 71-13-86-010-052-A ** ON A/C NOT FOR ALL (1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
B. Get Access
(1) Make sure that the fan cowl doors are open and safetied to the thrust reverser doors with the hold open brace.
(2) If not, open the fan cowl doors with the sling (Ref. AMM TASK 71-13-00-010-805).
(3) Put an ACCESS PLATFORM 1M(3 FT) in position.
4. Procedure(1) Make sure that the fan cowl doors are open and safetied to the thrust reverser doors with the hold open brace.
(2) If not, open the fan cowl doors with the sling (Ref. AMM TASK 71-13-00-010-805).
(3) Put an ACCESS PLATFORM 1M(3 FT) in position.
Subtask 71-13-86-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Hold Open Rod (HOR) Bracket Bolts
(1) Remove the bolts from the HOR bracket assemblies on the left side of the engine.
(a) Remove the nut (3), washer (2) and bolt (1) from the fan cowl HOR bracket assembly.
(b) Remove the nut (3), washer (2) and bolt (4) from the thrust reverser HOR bracket assembly.
(2) Remove the bolts from the HOR bracket assemblies on the right side of the engine.
(a) Remove the nut (10), washer (11) and bolt (12) from the fan cowl HOR bracket assembly.
(b) Remove the nut (10), washer (11) and bolt (13) from the thrust reverser HOR bracket assembly.
(1) Remove the bolts from the HOR bracket assemblies on the left side of the engine.
(a) Remove the nut (3), washer (2) and bolt (1) from the fan cowl HOR bracket assembly.
(b) Remove the nut (3), washer (2) and bolt (4) from the thrust reverser HOR bracket assembly.
(2) Remove the bolts from the HOR bracket assemblies on the right side of the engine.
(a) Remove the nut (10), washer (11) and bolt (12) from the fan cowl HOR bracket assembly.
(b) Remove the nut (10), washer (11) and bolt (13) from the thrust reverser HOR bracket assembly.
Left HOR Bracket Bolts