Removal of the Integrated Drive Generator (IDG) Access Door [CFML]
TASK 71-13-45-000-802-A
Removal of the Integrated Drive Generator (IDG) Access Door
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 71-13-45-941-052-A
Subtask 71-13-45-020-051-A
[Rev.10 from 2021]
2026.04.01 05:44:12 UTC
Removal of the Integrated Drive Generator (IDG) Access Door
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING:
YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
ZONE: 400
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 71-13-45-941-052-A
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
4. Procedure(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate:
- The ENG/MODE selector switch, and
- The ENG/MASTER 1(2) control switch.
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 71-13-45-020-051-A
A. Removal of the IDG Access Door from the Left Fan Cowl Door
(1) Release the captive studs (2).
(2) Remove the IDG access door (1) from the fan cowl door (7).
(3) Remove the lanyard (5) attached with the bolt (4) and the nut (6) from the IDG access door (1).
(4) Discard the nut (6).
(5) Remove the studs (2) and the washers (3) from the IDG access door (1). Keep the studs (2) and discard the washers (3).
(1) Release the captive studs (2).
(2) Remove the IDG access door (1) from the fan cowl door (7).
(3) Remove the lanyard (5) attached with the bolt (4) and the nut (6) from the IDG access door (1).
(4) Discard the nut (6).
(5) Remove the studs (2) and the washers (3) from the IDG access door (1). Keep the studs (2) and discard the washers (3).
IDG Access Door