Detailed Inspection of Outer Wing, Trailing Edge Overwing Panel Fittings
TASK 57-51-00-220-803-A
Detailed Inspection of Outer Wing, Trailing Edge Overwing Panel Fittings
Refer to the MPD TASK: 575154-01
DETAILED INSPECTION OF OUTER WING, TRAILING EDGE OVERWING PANEL FITTINGS
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 57-51-00-941-088-A ** ON A/C NOT FOR ALL
Subtask 57-51-00-110-096-A ** ON A/C NOT FOR ALL
Subtask 57-51-00-410-091-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:31:10 UTC
Detailed Inspection of Outer Wing, Trailing Edge Overwing Panel Fittings
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
CAUTION:
BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
1. Reason for the Job- DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
- DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
- MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
Refer to the MPD TASK: 575154-01
DETAILED INSPECTION OF OUTER WING, TRAILING EDGE OVERWING PANEL FITTINGS
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT) |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| 98D27803000000 | 1 | LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 571 | MLG BAY |
| 671 | MLG BAY |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 27-00-00-080-002-A | Removal of the Flap/Slat Control-Lever Locking Tool (98D27803000000) |
| TASK 27-00-00-480-002-A | Installation of the Flap/Slat Control-Lever Locking Tool (98D27803000000) |
| TASK 27-50-00-866-008-A | Extension of the Flaps on the Ground |
| TASK 27-50-00-866-008-A-01 | Extension of the Flaps/Slats on the Ground |
| TASK 27-50-00-866-009-A | Retraction of the Flaps on the Ground |
| TASK 27-50-00-866-009-A-01 | Retraction of the Flaps/Slats on the Ground |
| TASK 57-51-42-000-002-A | Removal of the Overwing Panel |
| TASK 57-51-42-400-002-A | Installation of the Overwing Panel |
| SRM 575121 | (for corrective action) |
Subtask 57-51-00-941-088-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Fully extend the flaps (Ref. AMM TASK 27-50-00-866-008).
(2) Install the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION on the flap/slat control lever (Ref. AMM TASK 27-00-00-480-002).
(3) Put a WARNING NOTICE(S) in the cockpit to tell persons not to operate the flaps or slats.
(4) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
Subtask 57-51-00-865-116-A ** ON A/C NOT FOR ALL (1) Fully extend the flaps (Ref. AMM TASK 27-50-00-866-008).
(2) Install the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION on the flap/slat control lever (Ref. AMM TASK 27-00-00-480-002).
(3) Put a WARNING NOTICE(S) in the cockpit to tell persons not to operate the flaps or slats.
(4) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 57-51-00-010-092-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1 | 6CV | B07 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1 | 6CV | B02 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FLIGHT CONTROLS/FLP/CTL AND/MONG/SYS2 | 8CV | Q21 |
| 121VU | FLIGHT CONTROLS/SEC3/SPLY | 21CE3 | Q19 |
| 121VU | FLIGHT CONTROLS/SEC2/SPLY | 21CE2 | Q18 |
C. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT) in position below the applicable zone 571(671).
(2) Remove the applicable overwing panel (Ref. AMM TASK 57-51-42-000-002).
4. Procedure(1) Put the ACCESS PLATFORM 4M (13 FT) in position below the applicable zone 571(671).
(2) Remove the applicable overwing panel (Ref. AMM TASK 57-51-42-000-002).
Subtask 57-51-00-110-096-A ** ON A/C NOT FOR ALL
A. Preparation for Inspection
(1) Use a clean Textile-Lint free Cotton - (Material No.14SBA1) , made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) , to clean the applicable inspection area.
Subtask 57-51-00-220-084-A ** ON A/C NOT FOR ALL (1) Use a clean Textile-Lint free Cotton - (Material No.14SBA1) , made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) , to clean the applicable inspection area.
B. Detailed Inspection of Outer Wing, Trailing-Edge Overwing-Panel Fittings
(1) Examine and make sure that:
5. Close-up(1) Examine and make sure that:
- There is no damage
- There are no cracks or scores
- There is no corrosion
- The surface protection is in the correct condition.
NOTE: If necessary, refer to the SRM 575121 for the correct repair procedure.
Subtask 57-51-00-410-091-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the applicable overwing panel (Ref. AMM TASK 57-51-42-400-002).
(3) Remove the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION from the flap/slat control lever (Ref. AMM TASK 27-00-00-080-002).
(4) Fully retract the flaps (Ref. AMM TASK 27-50-00-866-009).
Subtask 57-51-00-865-117-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the applicable overwing panel (Ref. AMM TASK 57-51-42-400-002).
(3) Remove the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION from the flap/slat control lever (Ref. AMM TASK 27-00-00-080-002).
(4) Fully retract the flaps (Ref. AMM TASK 27-50-00-866-009).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 57-51-00-942-089-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1 | 6CV | B07 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1 | 6CV | B02 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FLIGHT CONTROLS/FLP/CTL AND/MONG/SYS2 | 8CV | Q21 |
| 121VU | FLIGHT CONTROLS/SEC3/SPLY | 21CE3 | Q19 |
| 121VU | FLIGHT CONTROLS/SEC2/SPLY | 21CE2 | Q18 |
C. Removal of Equipment
(1) Remove the safety barriers.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Remove the safety barriers.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Outer Wing, Trailing-Edge Overwing-Panel Fittings