W DOC AIRBUS | AMM A320F

Detailed Inspection of Outer Wing, Trailing Edge Overwing Panel Fittings


TASK 57-51-00-220-803-A
Detailed Inspection of Outer Wing, Trailing Edge Overwing Panel Fittings


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
CAUTION: BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
  • MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
ZONE: 571
ZONE: 671
1. Reason for the Job
Refer to the MPD TASK: 575154-01
DETAILED INSPECTION OF OUTER WING, TRAILING EDGE OVERWING PANEL FITTINGS
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)
No specific
AR
SAFETY BARRIER(S)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
98D27803000000
1
LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
571
MLG BAY
671
MLG BAY
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 27-00-00-080-002-A
Removal of the Flap/Slat Control-Lever Locking Tool (98D27803000000)
TASK 27-00-00-480-002-A
Installation of the Flap/Slat Control-Lever Locking Tool (98D27803000000)
TASK 27-50-00-866-008-A
Extension of the Flaps on the Ground
TASK 27-50-00-866-008-A-01
Extension of the Flaps/Slats on the Ground
TASK 27-50-00-866-009-A
Retraction of the Flaps on the Ground
TASK 27-50-00-866-009-A-01
Retraction of the Flaps/Slats on the Ground
TASK 57-51-42-000-002-A
Removal of the Overwing Panel
TASK 57-51-42-400-002-A
Installation of the Overwing Panel
SRM 575121
(for corrective action)
3. Job Set-up
Subtask 57-51-00-941-088-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Fully extend the flaps (Ref. AMM TASK 27-50-00-866-008).
   (2) Install the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION on the flap/slat control lever (Ref. AMM TASK 27-00-00-480-002).
   (3) Put a WARNING NOTICE(S) in the cockpit to tell persons not to operate the flaps or slats.
   (4) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
Subtask 57-51-00-865-116-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB07
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB02
** ON A/C NOT FOR ALL
121VUFLIGHT CONTROLS/FLP/CTL AND/MONG/SYS28CVQ21
121VUFLIGHT CONTROLS/SEC3/SPLY21CE3Q19
121VUFLIGHT CONTROLS/SEC2/SPLY21CE2Q18
Subtask 57-51-00-010-092-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put the ACCESS PLATFORM 4M (13 FT) in position below the applicable zone 571(671).
   (2) Remove the applicable overwing panel (Ref. AMM TASK 57-51-42-000-002).
4. Procedure
Subtask 57-51-00-110-096-A ** ON A/C NOT FOR ALL
A. Preparation for Inspection
   (1) Use a clean Textile-Lint free Cotton - (Material No.14SBA1) , made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) , to clean the applicable inspection area.
Subtask 57-51-00-220-084-A ** ON A/C NOT FOR ALL
B. Detailed Inspection of Outer Wing, Trailing-Edge Overwing-Panel Fittings
   (1) Examine and make sure that:
  • There is no damage
  • There are no cracks or scores
  • There is no corrosion
  • The surface protection is in the correct condition.
NOTE: If necessary, refer to the SRM 575121 for the correct repair procedure.
5. Close-up
Subtask 57-51-00-410-091-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the applicable overwing panel (Ref. AMM TASK 57-51-42-400-002).
   (3) Remove the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION from the flap/slat control lever (Ref. AMM TASK 27-00-00-080-002).
   (4) Fully retract the flaps (Ref. AMM TASK 27-50-00-866-009).
Subtask 57-51-00-865-117-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB07
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB02
** ON A/C NOT FOR ALL
121VUFLIGHT CONTROLS/FLP/CTL AND/MONG/SYS28CVQ21
121VUFLIGHT CONTROLS/SEC3/SPLY21CE3Q19
121VUFLIGHT CONTROLS/SEC2/SPLY21CE2Q18
Subtask 57-51-00-942-089-A ** ON A/C NOT FOR ALL
C. Removal of Equipment
   (1) Remove the safety barriers.
   (2) Remove the access platform(s).
   (3) Remove the WARNING NOTICE(S).
   (4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
[Rev.10 from 2021] 2026.04.02 06:31:10 UTC