Removal of the Fixed Windows
TASK 56-11-12-000-001-A
Removal of the Fixed Windows
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 56-11-12-941-050-A
4. Procedure
Subtask 56-11-12-020-050-A
[Rev.10 from 2021]
2026.04.01 04:03:48 UTC
Removal of the Fixed Windows
WARNING:
YOU MUST MAKE SURE THAT YOU CAN HOLD THE COMPONENT BEFORE YOU REMOVE/INSTALL IT. THE COMPONENT IS HEAVY. IF IT FALLS, IT CAN CAUSE INJURY TO PERSONS AND DAMAGE TO EQUIPMENT.
CAUTION:
DO NOT USE SHARP AND/OR METALLIC TOOLS OR OBJECTS TO REMOVE/INSTALL THE WINDSHIELD OR A WINDOW. DO NOT USE A LEVER AGAINST THE EDGE OF THE WINDSHIELD OR WINDOW. IF YOU DO NOT OBEY THESE INSTRUCTIONS, YOU WILL CAUSE DAMAGE TO THE WINDSHIELD OR WINDOW.
1. Reason for the JobNOTE: Two persons are necessary for this procedure.
NOTE: This procedure is applicable to:
2. Job Set-up Information- The acrylic fixed windows (GKN supplier, P/N NH...)
- The glass fixed windows (PPG supplier, P/N NP...)
- The glass fixed windows (SGS supplier, P/Ns SPSA320-9-X-X and SPSA320-10-X- X only).
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 211 | COCKPIT |
| 212 | COCKPIT |
| FOR [7DG1] (WINDOW-FIXED, L) | |
| 211KW | |
| FOR [7DG2] (WINDOW-FIXED, R) | |
| 212KW | |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 56-11-12-941-050-A
A. Get Access
(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at zone 210, in front of the fixed window.
Subtask 56-11-12-865-050-A (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at zone 210, in front of the fixed window.
WARNING:
MAKE SURE THAT THE CIRCUIT BREAKERS RELATED TO THE WEATHER RADAR ARE OPENED, SAFETIED AND TAGGED.
B. Open, safety and tag this(these) circuit breaker(s):| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | COM NAV/RADAR/1 | 5SQ1 | K13 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/RADAR/2 | 5SQ2 | K14 |
| ** ON A/C ALL | |||
| FOR FIN: 7DG1 (WINDOWFIXED, L) | |||
| 122VU | ANTI ICE/WINDOWS/L | 4DG1 | X14 |
| 122VU | ANTI ICE/WHC/1 | 5DG1 | X13 |
| 123VU | ANTI ICE/L/WHSLD | 1DG1 | AF10 |
| FOR FIN: 7DG2 (WINDOWFIXED, R) | |||
| 122VU | ANTI ICE/WINDOWS/R | 4DG2 | W14 |
| 122VU | ANTI ICE/WHC/2 | 5DG2 | W13 |
| 123VU | ANTI ICE/R/WHSLD | 1DG2 | AF03 |
Subtask 56-11-12-020-050-A
A. Removal of the Fixed Window
(1) Removal of the lining panel:
(a) Removal of the lateral lining panel:
1 FOR [7DG1] (WINDOW-FIXED, L)
(c) Loosen the fasteners (2).
(d) Remove the lateral lining panel (8).
(2) Removal of the fixed window assembly:
(a) Disconnect the sensor (11) from the receptacle (14).
(b) Install the CAP - BLANKING on the disconnected electrical connector.
(c) Remove the screws (12).
(d) Remove the fixed window assembly (13).
(e) When you remove the fixed window, record the data in the IN-SERVICE WINDOW REMOVAL DATA GATHERING form to help Airbus continue to monitor it.
(1) Removal of the lining panel:
(a) Removal of the lateral lining panel:
1 FOR [7DG1] (WINDOW-FIXED, L)
- Remove the screws (3).
- Loosen the fasteners (4).
- Remove panel 211KW (5).
- Loosen the fasteners (1).
- Remove panel 212KW.
(c) Loosen the fasteners (2).
(d) Remove the lateral lining panel (8).
(2) Removal of the fixed window assembly:
(a) Disconnect the sensor (11) from the receptacle (14).
(b) Install the CAP - BLANKING on the disconnected electrical connector.
(c) Remove the screws (12).
(d) Remove the fixed window assembly (13).
(e) When you remove the fixed window, record the data in the IN-SERVICE WINDOW REMOVAL DATA GATHERING form to help Airbus continue to monitor it.
Fixed Windows - Inner Lining