Preparation for Installation
TASK 55-24-11-560-001-A
Preparation for Installation
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Referenced Information
3. Job Set-up
Subtask 55-24-11-860-052-A
Subtask 55-24-11-140-050-A
[Rev.10 from 2021]
2026.04.01 02:05:35 UTC
Preparation for Installation
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
WARNING:
DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
- FLUSH IT AWAY WITH CLEAN WATER
- GET MEDICAL AID.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
WARNING:
YOU MUST PUT ON AND ATTACH A SAFETY HARNESS BEFORE YOU START WORK:
- ON THE THS OR IN THE REAR FUSELAGE
- ON TOP OF THE WINGS OR PYLONS.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
CAUTION:
DO NOT CAUSE DAMAGE TO THE SURFACES. THE COMPONENTS ARE MADE OF CARBONFIBER REINFORCED PLASTIC.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SCRAPER - NON METALLIC |
| 98D27309001000 | 1 | NEUTRAL SETTING TOOL - ELEVATOR |
| 98D27903500000 | 2 | PIN-SIDE STICK LOCKING |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BBC1) | Non Aqueous Cleaner-- Naphta based and Alcohol - |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 29-10-00-864-001-A | Depressurize the Green Hydraulic System |
| TASK 29-10-00-864-002-A | Depressurize the Yellow Hydraulic System |
| TASK 29-10-00-864-003-A | Depressurize the Blue Hydraulic System |
Subtask 55-24-11-860-052-A
A. Aircraft Maintenance Configuration
(1) Make sure that the hydraulic systems are depressurized (Ref. AMM TASK 29-10-00-864-001), (Ref. AMM TASK 29-10-00-864-002), (Ref. AMM TASK 29-10-00-864-003).
(2) Make sure that the 98D27903500000 PIN-SIDE STICK LOCKING is in the CAPT and F/O side stick controllers.
(3) Make sure that the 98D27309001000 NEUTRAL SETTING TOOL - ELEVATOR are installed on the elevator.
(4) Make sure that the warning notices are in the flight compartment to tell persons not to operate the flight controls.
(5) Make sure that the warning notices are in position to tell persons not to operate the hydraulic systems.
(6) Make sure that the access platforms are in position at zone 335 and/or zone 345.
4. Procedure(1) Make sure that the hydraulic systems are depressurized (Ref. AMM TASK 29-10-00-864-001), (Ref. AMM TASK 29-10-00-864-002), (Ref. AMM TASK 29-10-00-864-003).
(2) Make sure that the 98D27903500000 PIN-SIDE STICK LOCKING is in the CAPT and F/O side stick controllers.
(3) Make sure that the 98D27309001000 NEUTRAL SETTING TOOL - ELEVATOR are installed on the elevator.
(4) Make sure that the warning notices are in the flight compartment to tell persons not to operate the flight controls.
(5) Make sure that the warning notices are in position to tell persons not to operate the hydraulic systems.
(6) Make sure that the access platforms are in position at zone 335 and/or zone 345.
Subtask 55-24-11-140-050-A
A. Cleaning
(1) Remove the old sealant from the mating surfaces of the tips and the elevator end caps. Use a SCRAPER - NON METALLIC.
Subtask 55-24-11-210-050-A (1) Remove the old sealant from the mating surfaces of the tips and the elevator end caps. Use a SCRAPER - NON METALLIC.
B. Visual Inspection
(1) Make sure that the related anchor nuts at the elevator end ribs are in a good condition.
(2) Examine the removed static dischargers for good condition.
Subtask 55-24-11-110-050-A (1) Make sure that the related anchor nuts at the elevator end ribs are in a good condition.
(2) Examine the removed static dischargers for good condition.
C. Cleaning
(1) Clean the mating surfaces with Non Aqueous Cleaner-- Naphta based and Alcohol - (Material No.08BBC1) .
(1) Clean the mating surfaces with Non Aqueous Cleaner-- Naphta based and Alcohol - (Material No.08BBC1) .