General Visual Inspection of Aft Emergency Exits, External Surface, LH/RH
TASK 52-22-11-200-007-A
General Visual Inspection of Aft Emergency Exits, External Surface, LH/RH
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 52-22-11-941-051-A ** ON A/C NOT FOR ALL
Subtask 52-22-11-210-055-A ** ON A/C NOT FOR ALL
Subtask 52-22-11-942-052-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:39:15 UTC
General Visual Inspection of Aft Emergency Exits, External Surface, LH/RH
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 835, 845 | |
| 834, 844 |
| REFERENCE | DESIGNATION |
|---|---|
| SRM 511100 | |
| SRM 512200 | |
| SRM 512300 | |
Subtask 52-22-11-941-051-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at closed aft emergency exit 834( 844).
Subtask 52-22-11-941-051-B ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at closed aft emergency exit 834( 844).
A. Get Access
(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at closed aft emergency exit 835( 845).
Subtask 52-22-11-110-050-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at closed aft emergency exit 835( 845).
B. Preparation of the Inspection Area
(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(2) If not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) .
4. Procedure(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(2) If not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) .
Subtask 52-22-11-210-055-A ** ON A/C NOT FOR ALL
A. Inspection
(1) Do a general visual inspection of the aft emergency exits, external surface, LH/RH for damage or discontinuities.
(2) Make sure that there is no:
(a) Corrosion damage:
5. Close-up(1) Do a general visual inspection of the aft emergency exits, external surface, LH/RH for damage or discontinuities.
(2) Make sure that there is no:
(a) Corrosion damage:
- If you find corrosion, refer to the Structural Repair Manual ( SRM 512200) for the corrosion types, inspection, removal and subsequent corrosion protection.
- If you find this type of damage, refer to the Structural Repair Manual ( SRM 511100) for the damage types, classification and corrective action.
- If you find this type of damage, refer to the Structural Repair Manual ( SRM 512300) for general data for paint layers.
Subtask 52-22-11-942-052-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Remove the access platform(s).
(1) Remove the access platform(s).
Aft Emergency-Exit External Surface