W DOC AIRBUS | AMM A320F

General Visual Inspection of Aft Passenger/Crew Door Skin, External Surface, LH/RH


TASK 52-13-00-210-002-A
General Visual Inspection of Aft Passenger/Crew Door Skin, External Surface, LH/RH


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 832
ZONE: 842
1. Reason for the Job
Refer to the MPD TASK: 521303-01
GENERAL VISUAL INSPECTION OF AFT PASSENGER/CREW DOOR SKIN, EXTERNAL SURFACE, LH/RH
NOTE: The effectivity of this task is "ALL". To know if this task is applicable for your aircraft, refer to the MPD task applicability and the weight variant data given in the SRM introduction.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
832
AFT PASSENGER/CREW DOOR
842
AFT PASSENGER/CREW DOOR
 D. Referenced Information
REFERENCE
DESIGNATION
SRM 51110001
(for corrective action)
SRM 51220001
(for corrective action)
3. Job Set-up
Subtask 52-13-00-010-063-A
A. Get Access
   (1) Put an ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position :
     (a) For the left passenger/crew door at the zone 832.
     (b) For the right passenger/crew door at the zone 842.
Subtask 52-13-00-110-052-A
B. Cleaning of the Structure
   (1) Clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a lint-free cotton cloth Textile-Lint free Cotton - (Material No.14SBA1) , if necessary.
4. Procedure
Subtask 52-13-00-210-055-A
A. Inspection
   (1) Do a visual inspection of the external surface of the aft passenger/crew door skin, left and right sides.
   (2) Make sure that there is no:
     (a) Corrosion damage:
- If you find corrosion damage, refer to the Structural Repair Manual SRM 51220001 for types, inspection, removal and corrosion protection.
     (b) Other damage (scratches, cracks, gouges, dents, creases):
- If you find other damage, refer to the Structural Repair Manual SRM 51110001 for damage classification and corrective action.
5. Close-up
Subtask 52-13-00-410-064-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.01 01:37:06 UTC