W DOC AIRBUS | AMM A320F

Cleaning of the Door Entry Drains


TASK 51-78-00-615-006-A
Cleaning of the Door Entry Drains


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
1
AIR SOURCE 0.3 TO 0.7 BAR (5 TO 10 PSI)- FILTERED, DRY
No specific
1
SCRAPER - NON METALLIC
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
3. Job Set-up
Subtask 51-78-00-010-057-A
A. Get Access
   (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the applicable passenger door.
   (2) Open the applicable passenger door.
   (3) Get access to the applicable water drain(s).
   (4) Remove the correct forward or aft floor panel(s) at the door entry position.
4. Procedure
Subtask 51-78-00-110-056-A
A. Cleaning Procedure
   (1) Clean the floor panel with the Non Aqueous Cleaner-General - - (Material No.08BAA9) and a clean lint-free cloth Textile-Lint free Cotton - (Material No.14SBA1) .
   (2) Make sure that the water drain collector(s) are clean and in the correct condition.
   (3) Remove the sealant/contamination with a SCRAPER - NON METALLIC and a clean lint-free cloth Textile-Lint free Cotton - (Material No.14SBA1)
   (4) Examine the condition of the drains:
     (a) Put water down the drain collector(s) and let it drain.
     (b) Make sure that the water drains away from below the fuselage.
   (5) If the water does not drain away from the drain collector(s):
     (a) Use a low pressure AIR SOURCE 0.3 TO 0.7 BAR (5 TO 10 PSI)- FILTERED, DRY attached to the drain collector(s) to remove the contamination.
     (b) Put water down the drain collector(s) and make sure that it drains away from below the fuselage.
5. Close-up
Subtask 51-78-00-410-057-A
A. Close Access
   (1) Install the entry-door floor panel(s) in the correct position(s).
   (2) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
[Rev.10 from 2021] 2026.04.01 01:35:04 UTC