Water Break Test
TASK 51-77-11-700-001-A
Water Break Test
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
3. Job Set-up
Subtask 51-77-11-010-051-A
Subtask 51-77-11-750-050-A
[Rev.10 from 2021]
2026.04.01 01:34:52 UTC
Water Break Test
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | PAPER - ABRASIVE (GRADE 400) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| No specific | demineralized water |
Subtask 51-77-11-010-051-A
A. There is no special job set-up for this task.
4. ProcedureSubtask 51-77-11-750-050-A
A. Do the Water Break Test
(1) Dry the repair area with a clean Textile-Lint free Cotton - (Material No.14SBA1) .
(2) Spray a thin coating of demineralized water on the repair area.
(4) A defect is shown when the demineralized water is repelled and forms into beads of water.
(5) If necessary, rub down the repair area with PAPER - ABRASIVE (GRADE 400) to remove the defect.
(6) If necessary, clean the repair area with demineralized water and a lint-free cloth.
(7) If necessary, repeat the water-break test until there are no defects on the repair area surface.
(8) Dry the repair area with a clean Textile-Lint free Cotton - (Material No.14SBA1) .
(1) Dry the repair area with a clean Textile-Lint free Cotton - (Material No.14SBA1) .
(2) Spray a thin coating of demineralized water on the repair area.
NOTE: A thick coating of demineralized water will not show all the defects on the repair area.
(3) Inspect the wetted surface to make sure the water forms a thin continuous coating. (4) A defect is shown when the demineralized water is repelled and forms into beads of water.
(5) If necessary, rub down the repair area with PAPER - ABRASIVE (GRADE 400) to remove the defect.
(6) If necessary, clean the repair area with demineralized water and a lint-free cloth.
(7) If necessary, repeat the water-break test until there are no defects on the repair area surface.
(8) Dry the repair area with a clean Textile-Lint free Cotton - (Material No.14SBA1) .
NOTE: On completion of the water-break test, do not touch the repair area. Do the repair quickly to prevent contamination.
(9) At the repair area apply new paint as necessary (Ref. SRM 51-75-12).