W DOC AIRBUS | AMM A320F

Inspect the APU Drain System (APS 3200)


TASK 49-17-00-200-001-A
Inspect the APU Drain System (APS 3200)


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
Torque wrench: range to between 0.495 and 0.405 m.daN (43.81 and 35.84 lbf.in ) T
No specific
Torque wrench: range to between 3.39 and 3.05 m.daN (25.00 and 22.49 lbf.ft ) T
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
315AL, 316AR
 C. Referenced Information
REFERENCE
DESIGNATION
3. Job Set-up
Subtask 49-17-00-865-050-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
Subtask 49-17-00-010-050-A ** ON A/C NOT FOR ALL
B. Gain Access
   (1) Put the access platform below the APU compartment.
   (2) Open the APU access doors 315AL 316AR.
4. Procedure
Subtask 49-17-00-020-050-A ** ON A/C NOT FOR ALL
A. Preparation for Inspection
   (1) Remove the support clamps, disconnect the following drain lines from the engine components and the drain mast:
  • combuster drain
  • exhaust muffler drain
  • air by-pass plenum drain
  • IGV actuator seal
  • fuel control unit seal
  • oil pump seal
  • forward bearing seal witness drain
  • bleed control valve seal drain
Subtask 49-17-00-200-050-A ** ON A/C NOT FOR ALL
B. Inspection of the Drains
WARNING: WHEN YOU USE COMPRESSED AIR:
  • USE THE CORRECT PROTECTION (FACE SHIELD OR GOGGLES)
  • DO NOT POINT THE AIRFLOW AT YOURSELF OR OTHER PERSONS.
LOOSE PARTICLES AND/OR HIGH PRESSURE AIR CAN CAUSE INJURY.
   (1) Examine the drain lines and all apertures for blockage. Any blockage must be cleared by blowing through with dry compressed air.
   (2) Examine the drain lines and connectors for cracks, distortion, kinks, and damaged threads. Any such damaged lines must be repaired or replaced.
   (3) Examine the drain mast for damage and cleanliness. No damage is permitted. Clean as necessary.
Subtask 49-17-00-420-050-A ** ON A/C NOT FOR ALL
C. Installation of the drain tubes
   (1) Install the tubes and support clamps previously removed as detailed in paragraph 3.A.
   (2) Torque all the tube nuts to between 3.39 and 3.05 m.daN (25.00 and 22.49 lbf.ft ) T.
   (3) Torque all support clamp bolts to between 0.495 and 0.405 m.daN (43.81 and 35.84 lbf.in )
T.
5. Close-up
Subtask 49-17-00-410-050-A ** ON A/C NOT FOR ALL
Subtask 49-17-00-865-051-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
[Rev.10 from 2021] 2026.04.01 01:28:23 UTC