Leak Check of the Components in the Air Supply System


TASK 38-41-00-790-001-A
Leak Check of the Components in the Air Supply System


NOTE: You can use the bleed air supply as an alternative to the ground air supply to do the leak check.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 1M(3 FT)
No specific
1
GROUND AIR-SUPPLY UNIT(HIGH PRESSURE)
 B. Consumable Materials
REFERENCE
DESIGNATION
No specific
soap solution
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
171AL
3. Job Set-up
Subtask 38-41-00-941-053-A
A. Put the ACCESS PLATFORM 1M(3 FT) in position at Zone 171.
Subtask 38-41-00-010-055-A
B. Open the access panel 171AL.
Subtask 38-41-00-480-053-A
C. Connect the GROUND AIR-SUPPLY UNIT(HIGH PRESSURE) to the ground air-pressure port.
4. Procedure
Subtask 38-41-00-790-050-A
A. Do the Leak Check
   (1) Apply soap solution to the applicable connection(s).
   (2) Operate the ground air-supply cart and pressurize the potable water system to 44 +3 psi or -3 psi (3.0337 +0.2068 bar or -0.2068 bar).
   (3) Examine the connection(s) for leaks.
NOTE: Leaks are not permitted.
   (4) Clean the connection(s).
   (5) Release the pressure from the potable water system.
5. Close-up
Subtask 38-41-00-080-052-A
A. Disconnect the ground air-supply cart.
Subtask 38-41-00-410-056-A
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the potable-water service panel-door 171AL.
NOTE: Make sure that the latches are correctly locked and that the door makes a continuous surface with the skin of the aircraft.
   (3) Remove the access platform(s).