Removal of the HP Ground Connector
TASK 36-13-41-000-001-A
Removal of the HP Ground Connector
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 36-13-41-865-050-A
Subtask 36-13-41-020-050-A
[Rev.10 from 2021]
2026.04.01 12:38:06 UTC
Removal of the HP Ground Connector
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
FIN: 7300HM
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | 1 | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 2 | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 191BB |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 36-13-41-865-050-A
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 36-13-41-860-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR BLEED/ENG 1/CTL | 3HA1 | D12 |
| 49VU | AIR BLEED/ENG 1/MONG | 2HA1 | D11 |
| ** ON A/C ALL | |||
| 49VU | AIR BLEED/X FEED/VALVE/BAT | 2HV | D13 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR BLEED/ENG 2/MONG | 3HA2 | D12 |
| 49VU | AIR BLEED/ENG 1/CTL | 2HA1 | D11 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR BLEED/ENG 2/CTL | 3HA2 | Z23 |
| 122VU | AIR BLEED/ENG 2/MONG | 2HA2 | Z22 |
| ** ON A/C ALL | |||
| 122VU | AIR BLEED/X FEED VALVE/NORM | 1HV | Z20 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR BLEED/ENG 1/MONG | 3HA1 | Z23 |
| 122VU | AIR BLEED/ENG 2/CTL | 2HA2 | Z22 |
B. Aircraft Maintenance Configuration
(1) Put the WARNING NOTICE(S) in position:
Subtask 36-13-41-010-050-A 4. Procedure(1) Put the WARNING NOTICE(S) in position:
- in the cockpit on the Engine Control Panel 115VU to tell persons not to start the engine(s),
- in the cockpit on the AIR COND Overhead Control Panel 30VU to tell persons not to push in the APU BLEED pushbutton switch.
Subtask 36-13-41-020-050-A
A. Removal of the HP Ground Connector
(1) Hold the HP Ground Connector (3) and remove the nuts (1) with the washers (2) from the duct.
(2) Discard the nuts (1).
(3) Remove the HP Ground Connector (3) and the sealing ring (6) from the duct.
(4) Remove the check valve (5) and the O-ring (4) from the HP Ground Connector (3).
(5) Put the CAP - BLANKING in the open end of the duct.
(1) Hold the HP Ground Connector (3) and remove the nuts (1) with the washers (2) from the duct.
(2) Discard the nuts (1).
(3) Remove the HP Ground Connector (3) and the sealing ring (6) from the duct.
(4) Remove the check valve (5) and the O-ring (4) from the HP Ground Connector (3).
(5) Put the CAP - BLANKING in the open end of the duct.
HP Ground Connector 7300HM