Removal of the Static Probe
TASK 34-11-16-000-001-A
Removal of the Static Probe
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 34-11-16-860-054-A
Subtask 34-11-16-020-050-A ** ON A/C NOT FOR ALL
(2) Remove the two nuts (8), the washers (10) and the bolts (11).
(3) Disconnect the nut (1) and remove the static line (13).
(4) Put a PLUG - BLANKING on the nut (1).
(5) Remove the union (2).
(6) Remove the packing (4) and discard it.
(7) Remove the four nuts (3).
(8) Remove the static probe (5).
(9) Remove the packing (6) and discard it.
(10) Keep the bolts (7).
Subtask 34-11-16-020-050-B ** ON A/C NOT FOR ALL
(2) Remove the two nuts (8), the washers (10) and the bolts (11).
(3) Disconnect the nut (1) and remove the static line (13).
(4) Put a PLUG - BLANKING on the nut (1).
(5) Remove the union (2).
(6) Remove the packing (4) and discard it.
(7) Remove the four nuts (3).
(8) Remove the bonding strip (15).
(9) Remove the static probe (5).
(10) Remove the packing (6) and discard it.
(11) Keep the bolts (7).
[Rev.10 from 2021]
2026.04.01 04:01:21 UTC
Removal of the Static Probe
WARNING:
MAKE SURE THAT THE CIRCUIT BREAKERS RELATED TO THE WEATHER RADAR ARE OPENED, SAFETIED AND TAGGED.
WARNING:
MAKE SURE THAT:
- THE STATIC PROBE IS NOT HOT
- THE ELECTRICAL SUPPLY TO THE HEATING ELEMENT OF THE PROBE IS ISOLATED
WARNING:
BEFORE YOU OPEN PHC CIRCUIT BREAKERS 2DA1(2,3), OPEN PROBE HEATER CIRCUIT-BREAKERS 1DA1(2), 3DA1(2,3), 4DA1(2,3) AND 5DA1(2,3). IF YOU DO NOT OBEY THIS SEQUENCE:
- THE PROBES WILL BECOME TOO HOT.
- THIS CAN CAUSE DAMAGE TO EQUIPMENT AND INJURY TO MAINTENANCE PERSONNEL.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | PLUG - BLANKING |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 120 | AVIONICS COMPARTMENT |
| FOR [7DA1] (PROBE-L STATIC, 1) | |
| FOR [7DA2] (PROBE-L STATIC, 2) | |
| FOR [8DA1] (PROBE-R STATIC, 1) | |
| FOR [8DA2] (PROBE-R STATIC, 2) | |
| 824 | |
| FOR [7DA3] (PROBE-L STATIC, 3) | |
| FOR [8DA3] (PROBE-R STATIC, 3) | |
| 811 | |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 34-11-16-860-054-A
A. Aircraft Maintenance Configuration
(1) Remove the protective covers from the sensors and the probes (AOA, static, Pitot and TAT).
Subtask 34-11-16-865-061-A (1) Remove the protective covers from the sensors and the probes (AOA, static, Pitot and TAT).
B. Table of the circuit breakers used in this procedure:
Subtask 34-11-16-941-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | ENGINE/2/FADEC A/AND EIU 2 | 2KS2 | A05 |
| 49VU | ENGINE/1/FADEC A/AND EIU 1 | 2KS1 | A04 |
C. Safety Precautions
(1) In the cockpit, on overhead control and indicating panel 25VU:
(a) Make sure that the PROBE/WINDOW HEAT pushbutton switch is released (the ON legend is off).
(b) Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 34-11-16-865-050-A (1) In the cockpit, on overhead control and indicating panel 25VU:
(a) Make sure that the PROBE/WINDOW HEAT pushbutton switch is released (the ON legend is off).
(b) Make sure that this(these) circuit breaker(s) is(are) closed:
- 2KS1
- 2KS2.
D. Open, safety and tag these circuit breakers in this sequence:
Subtask 34-11-16-010-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | COM NAV/RADAR/1 | 5SQ1 | K13 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/RADAR/2 | 5SQ2 | K14 |
| ** ON A/C ALL | |||
| FOR FIN: 8DA1 (PROBER STATIC, 1) FOR FIN: 7DA1 (PROBEL STATIC, 1) | |||
| 122VU | ANTI ICE/PROBES/1/TAT | 1DA1 | Z12 |
| 49VU | ANTI ICE/PROBES/PITOT/1 | 3DA1 | D02 |
| 49VU | ANTI ICE/PROBES/AOA/1 | 4DA1 | D04 |
| 122VU | ANTI ICE/PROBES/1/STATIC | 5DA1 | Z13 |
| FOR FIN: 8DA2 (PROBER STATIC, 2) FOR FIN: 7DA2 (PROBEL STATIC, 2) | |||
| 122VU | ANTI ICE/PROBES/2/TAT | 1DA2 | Y15 |
| 122VU | ANTI ICE/PROBES/2/PITOT | 3DA2 | Y14 |
| 122VU | ANTI ICE/PROBES/2/AOA | 4DA2 | Y13 |
| 122VU | ANTI ICE/PROBES/2/STATIC | 5DA2 | Y11 |
| FOR FIN: 8DA3 (PROBER STATIC, 3) FOR FIN: 7DA3 (PROBEL STATIC, 3) | |||
| 122VU | ANTI ICE/PROBES/3/PITOT | 3DA3 | Z16 |
| 122VU | ANTI ICE/PROBES/3/AOA | 4DA3 | Z15 |
| 122VU | ANTI ICE/PROBES/3/STATIC | 5DA3 | Z14 |
| FOR FIN: 8DA1 (PROBER STATIC, 1) FOR FIN: 7DA1 (PROBEL STATIC, 1) | |||
| 49VU | ANTI ICE/PROBES/PHC/1 | 2DA1 | D03 |
| FOR FIN: 8DA2 (PROBER STATIC, 2) FOR FIN: 7DA2 (PROBEL STATIC, 2) | |||
| 122VU | ANTI ICE/PROBES/PHC/2 | 2DA2 | Y12 |
| FOR FIN: 8DA3 (PROBER STATIC, 3) FOR FIN: 7DA3 (PROBEL STATIC, 3) | |||
| 122VU | ANTI ICE/PROBES/PHC/3 | 2DA3 | Y16 |
E. Get Access
(1) Put the ACCESS PLATFORM 1M(3 FT) in position at the zone 128 for the static probes 7DA1, 8DA1, 7DA2 and 8DA2.
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the zone 120 for static probes 7DA3 and 8DA3.
(3) Open the access door :
(a) FOR [7DA1] (PROBE-L STATIC, 1), [8DA1] (PROBE-R STATIC, 1), [7DA2] (PROBE-L STATIC, 2), [8DA2] (PROBE-R STATIC, 2)
824
(b) FOR [7DA3] (PROBE-L STATIC, 3), [8DA3] (PROBE-R STATIC, 3)
811
4. Procedure(1) Put the ACCESS PLATFORM 1M(3 FT) in position at the zone 128 for the static probes 7DA1, 8DA1, 7DA2 and 8DA2.
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the zone 120 for static probes 7DA3 and 8DA3.
(3) Open the access door :
(a) FOR [7DA1] (PROBE-L STATIC, 1), [8DA1] (PROBE-R STATIC, 1), [7DA2] (PROBE-L STATIC, 2), [8DA2] (PROBE-R STATIC, 2)
824
(b) FOR [7DA3] (PROBE-L STATIC, 3), [8DA3] (PROBE-R STATIC, 3)
811
Subtask 34-11-16-020-050-A ** ON A/C NOT FOR ALL
CAUTION:
BE VERY CAREFUL WITH THE STATIC PROBES WHEN YOU REMOVE/INSTALL THEM:
A. Removal of the Static Probe - DO NOT LET THEM FALL
- DO NOT BEND THEM
- DO NOT CAUSE THEM SCRATCHES.
NOTE: This procedure is the same for the six static probes.
(1) Remove the covers (12). (2) Remove the two nuts (8), the washers (10) and the bolts (11).
(3) Disconnect the nut (1) and remove the static line (13).
(4) Put a PLUG - BLANKING on the nut (1).
(5) Remove the union (2).
(6) Remove the packing (4) and discard it.
(7) Remove the four nuts (3).
(8) Remove the static probe (5).
(9) Remove the packing (6) and discard it.
(10) Keep the bolts (7).
CAUTION:
BE VERY CAREFUL WITH THE STATIC PROBES WHEN YOU REMOVE/INSTALL THEM:
A. Removal of the Static Probe - DO NOT LET THEM FALL
- DO NOT BEND THEM
- DO NOT CAUSE THEM SCRATCHES.
NOTE: This procedure is the same for the six static probes.
(1) Remove the covers (12). (2) Remove the two nuts (8), the washers (10) and the bolts (11).
(3) Disconnect the nut (1) and remove the static line (13).
(4) Put a PLUG - BLANKING on the nut (1).
(5) Remove the union (2).
(6) Remove the packing (4) and discard it.
(7) Remove the four nuts (3).
(8) Remove the bonding strip (15).
(9) Remove the static probe (5).
(10) Remove the packing (6) and discard it.
(11) Keep the bolts (7).
Static Probe