W DOC AIRBUS | AMM A320F

Removal of the Static Probe


TASK 34-11-16-000-001-A
Removal of the Static Probe


WARNING: MAKE SURE THAT THE CIRCUIT BREAKERS RELATED TO THE WEATHER RADAR ARE OPENED, SAFETIED AND TAGGED.
WARNING: MAKE SURE THAT:
  • THE STATIC PROBE IS NOT HOT
  • THE ELECTRICAL SUPPLY TO THE HEATING ELEMENT OF THE PROBE IS ISOLATED
BEFORE YOU START THE TASK.
WARNING: BEFORE YOU OPEN PHC CIRCUIT BREAKERS 2DA1(2,3), OPEN PROBE HEATER CIRCUIT-BREAKERS 1DA1(2), 3DA1(2,3), 4DA1(2,3) AND 5DA1(2,3). IF YOU DO NOT OBEY THIS SEQUENCE: - THE PROBES WILL BECOME TOO HOT. - THIS CAN CAUSE DAMAGE TO EQUIPMENT AND INJURY TO MAINTENANCE PERSONNEL.
ZONE: 120
FIN: 7DA1
FIN: 7DA2
FIN: 7DA3
FIN: 8DA1
FIN: 8DA2
FIN: 8DA3
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
PLUG - BLANKING
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
120
AVIONICS COMPARTMENT
FOR [7DA1] (PROBE-L STATIC, 1)
FOR [7DA2] (PROBE-L STATIC, 2)
FOR [8DA1] (PROBE-R STATIC, 1)
FOR [8DA2] (PROBE-R STATIC, 2)
824
FOR [7DA3] (PROBE-L STATIC, 3)
FOR [8DA3] (PROBE-R STATIC, 3)
811
 C. Referenced Information
REFERENCE
DESIGNATION
F Static Probe ** ON A/C NOT FOR ALL
F Static Probe ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 34-11-16-860-054-A
A. Aircraft Maintenance Configuration
   (1) Remove the protective covers from the sensors and the probes (AOA, static, Pitot and TAT).
Subtask 34-11-16-865-061-A
B. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
49VUENGINE/1/FADEC A/AND EIU 12KS1A04
Subtask 34-11-16-941-050-A
C. Safety Precautions
   (1) In the cockpit, on overhead control and indicating panel 25VU:
     (a) Make sure that the PROBE/WINDOW HEAT pushbutton switch is released (the ON legend is off).
     (b) Make sure that this(these) circuit breaker(s) is(are) closed:
  • 2KS1
  • 2KS2.
Subtask 34-11-16-865-050-A
D. Open, safety and tag these circuit breakers in this sequence:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUCOM NAV/RADAR/15SQ1K13
** ON A/C NOT FOR ALL
121VUCOM NAV/RADAR/25SQ2K14
** ON A/C ALL
FOR FIN: 8DA1 (PROBER STATIC, 1) FOR FIN: 7DA1 (PROBEL STATIC, 1)
122VUANTI ICE/PROBES/1/TAT1DA1Z12
49VUANTI ICE/PROBES/PITOT/13DA1D02
49VUANTI ICE/PROBES/AOA/14DA1D04
122VUANTI ICE/PROBES/1/STATIC5DA1Z13
FOR FIN: 8DA2 (PROBER STATIC, 2) FOR FIN: 7DA2 (PROBEL STATIC, 2)
122VUANTI ICE/PROBES/2/TAT1DA2Y15
122VUANTI ICE/PROBES/2/PITOT3DA2Y14
122VUANTI ICE/PROBES/2/AOA4DA2Y13
122VUANTI ICE/PROBES/2/STATIC5DA2Y11
FOR FIN: 8DA3 (PROBER STATIC, 3) FOR FIN: 7DA3 (PROBEL STATIC, 3)
122VUANTI ICE/PROBES/3/PITOT3DA3Z16
122VUANTI ICE/PROBES/3/AOA4DA3Z15
122VUANTI ICE/PROBES/3/STATIC5DA3Z14
FOR FIN: 8DA1 (PROBER STATIC, 1) FOR FIN: 7DA1 (PROBEL STATIC, 1)
49VUANTI ICE/PROBES/PHC/12DA1D03
FOR FIN: 8DA2 (PROBER STATIC, 2) FOR FIN: 7DA2 (PROBEL STATIC, 2)
122VUANTI ICE/PROBES/PHC/22DA2Y12
FOR FIN: 8DA3 (PROBER STATIC, 3) FOR FIN: 7DA3 (PROBEL STATIC, 3)
122VUANTI ICE/PROBES/PHC/32DA3Y16
Subtask 34-11-16-010-050-A
E. Get Access
   (1) Put the ACCESS PLATFORM 1M(3 FT) in position at the zone 128 for the static probes 7DA1, 8DA1, 7DA2 and 8DA2.
   (2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the zone 120 for static probes 7DA3 and 8DA3.
   (3) Open the access door :
     (a) FOR [7DA1] (PROBE-L STATIC, 1), [8DA1] (PROBE-R STATIC, 1), [7DA2] (PROBE-L STATIC, 2), [8DA2] (PROBE-R STATIC, 2)
824
     (b) FOR [7DA3] (PROBE-L STATIC, 3), [8DA3] (PROBE-R STATIC, 3)
811
4. Procedure
Subtask 34-11-16-020-050-A ** ON A/C NOT FOR ALL
CAUTION: BE VERY CAREFUL WITH THE STATIC PROBES WHEN YOU REMOVE/INSTALL THEM:
  • DO NOT LET THEM FALL
  • DO NOT BEND THEM
  • DO NOT CAUSE THEM SCRATCHES.
STATIC PROBES CONTAIN SENSITIVE ELECTRONIC EQUIPMENT WHICH CAN EASILY BE DAMAGED.
A. Removal of the Static Probe
NOTE: This procedure is the same for the six static probes.
   (1) Remove the covers (12).
   (2) Remove the two nuts (8), the washers (10) and the bolts (11).
   (3) Disconnect the nut (1) and remove the static line (13).
   (4) Put a PLUG - BLANKING on the nut (1).
   (5) Remove the union (2).
   (6) Remove the packing (4) and discard it.
   (7) Remove the four nuts (3).
   (8) Remove the static probe (5).
   (9) Remove the packing (6) and discard it.
   (10) Keep the bolts (7).
Subtask 34-11-16-020-050-B ** ON A/C NOT FOR ALL
CAUTION: BE VERY CAREFUL WITH THE STATIC PROBES WHEN YOU REMOVE/INSTALL THEM:
  • DO NOT LET THEM FALL
  • DO NOT BEND THEM
  • DO NOT CAUSE THEM SCRATCHES.
STATIC PROBES CONTAIN SENSITIVE ELECTRONIC EQUIPMENT WHICH CAN EASILY BE DAMAGED.
A. Removal of the Static Probe
NOTE: This procedure is the same for the six static probes.
   (1) Remove the covers (12).
   (2) Remove the two nuts (8), the washers (10) and the bolts (11).
   (3) Disconnect the nut (1) and remove the static line (13).
   (4) Put a PLUG - BLANKING on the nut (1).
   (5) Remove the union (2).
   (6) Remove the packing (4) and discard it.
   (7) Remove the four nuts (3).
   (8) Remove the bonding strip (15).
   (9) Remove the static probe (5).
   (10) Remove the packing (6) and discard it.
   (11) Keep the bolts (7).
[Rev.10 from 2021] 2026.04.01 04:01:21 UTC