Removal of the Check Valve and of the Rain Repellent Blowout Reservoir
TASK 30-45-45-000-001-A
Removal of the Check Valve and of the Rain Repellent Blowout Reservoir
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 30-45-45-865-054-A
Subtask 30-45-45-020-052-A
[Rev.10 from 2021]
2026.04.01 00:31:25 UTC
Removal of the Check Valve and of the Rain Repellent Blowout Reservoir
WARNING:
DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
- FLUSH IT AWAY WITH CLEAN WATER
- GET MEDICAL AID.
CAUTION:
MAKE SURE THAT THE FLUID DOES NOT STAY ON THE AIRCRAFT STRUCTURE. IF THE FLUID GETS ON THE AIRCRAFT STRUCTURE, WASH IT OFF IMMEDIATELY WITH SOAP AND WATER.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 120 | AVIONICS COMPARTMENT |
| 811 |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 30-45-45-865-054-A
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 30-45-45-010-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | ANTI ICE/RAIN/RPLNT/CAPT | 1DB1 | D01 |
| 122VU | ANTI ICE/RAIN/RPLNT/F/O | 1DB2 | W11 |
B. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(2) Open the access door 811.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(2) Open the access door 811.
Subtask 30-45-45-020-052-A
A. Removal of the Check Valve.
(1) Disconnect the elbow (1) from the union (2).
(2) Disconnect the line (15).
(3) Remove the clamps (8) and (10).
(4) Remove the union (2).
(5) Remove the check valve (4).
(6) Remove the union (6).
(7) Discard the o-rings (3), (5) and (7).
(8) Remove the plugs (17) and (12) from the removed component and discard the O-rings (16) and (11).
(9) Remove the union (14) from the removed component and discard the O-ring (13).
Subtask 30-45-45-020-050-A (1) Disconnect the elbow (1) from the union (2).
(2) Disconnect the line (15).
(3) Remove the clamps (8) and (10).
(4) Remove the union (2).
(5) Remove the check valve (4).
(6) Remove the union (6).
(7) Discard the o-rings (3), (5) and (7).
(8) Remove the plugs (17) and (12) from the removed component and discard the O-rings (16) and (11).
(9) Remove the union (14) from the removed component and discard the O-ring (13).
B. Removal of the Reservoir:
(1) Remove the reservoir (9).
(2) Put the PLUG-BLANKING in each disconnected line end.
(1) Remove the reservoir (9).
(2) Put the PLUG-BLANKING in each disconnected line end.
Rain Repellent Blowout Reservoir