W DOC AIRBUS | AMM A320F

Removal of the Check Valve and of the Rain Repellent Blowout Reservoir


TASK 30-45-45-000-001-A
Removal of the Check Valve and of the Rain Repellent Blowout Reservoir


WARNING: DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
  • FLUSH IT AWAY WITH CLEAN WATER
  • GET MEDICAL AID.
CAUTION: MAKE SURE THAT THE FLUID DOES NOT STAY ON THE AIRCRAFT STRUCTURE. IF THE FLUID GETS ON THE AIRCRAFT STRUCTURE, WASH IT OFF IMMEDIATELY WITH SOAP AND WATER.
ZONE: 120
FIN: 5DM
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
120
AVIONICS COMPARTMENT
811
 C. Referenced Information
REFERENCE
DESIGNATION
3. Job Set-up
Subtask 30-45-45-865-054-A
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUANTI ICE/RAIN/RPLNT/CAPT1DB1D01
122VUANTI ICE/RAIN/RPLNT/F/O1DB2W11
Subtask 30-45-45-010-050-A
B. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
   (2) Open the access door 811.
4. Procedure
Subtask 30-45-45-020-052-A
A. Removal of the Check Valve.
   (1) Disconnect the elbow (1) from the union (2).
   (2) Disconnect the line (15).
   (3) Remove the clamps (8) and (10).
   (4) Remove the union (2).
   (5) Remove the check valve (4).
   (6) Remove the union (6).
   (7) Discard the o-rings (3), (5) and (7).
   (8) Remove the plugs (17) and (12) from the removed component and discard the O-rings (16) and (11).
   (9) Remove the union (14) from the removed component and discard the O-ring (13).
Subtask 30-45-45-020-050-A
B. Removal of the Reservoir:
   (1) Remove the reservoir (9).
   (2) Put the PLUG-BLANKING in each disconnected line end.
[Rev.10 from 2021] 2026.04.01 00:31:25 UTC