Modification of the Pylon Anti-Ice Duct
TASK 30-21-49-820-010-A
Modification of the Pylon Anti-Ice Duct
To prevent incorrect installation of the duct and supply retention of the related segments.
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 30-21-49-010-127-A ** ON A/C NOT FOR ALL
Subtask 30-21-49-820-055-A ** ON A/C NOT FOR ALL
Subtask 30-21-49-410-109-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:29:44 UTC
Modification of the Pylon Anti-Ice Duct
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
1. Reason for the JobTo prevent incorrect installation of the duct and supply retention of the related segments.
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-20-000-040-A | Removal of the Power Plant |
| TASK 71-00-20-000-040-A-01 | Removal of the Power Plant with the Engine Positioner TWW 75E (MIAG) |
| TASK 71-00-20-400-040-A | Installation of the Power Plant |
| TASK 71-00-20-400-040-A-01 | Installation of the Power Plant with the Engine Positioner TWW 75E (MIAG) |
Subtask 30-21-49-010-127-A ** ON A/C NOT FOR ALL
A. Lower the power plant (Ref. AMM TASK 71-00-20-000-040).
4. ProcedureNOTE: Lower the engine between 0.3 m (1 ft.) and 0.4 m (1.3 ft.)
Subtask 30-21-49-820-055-A ** ON A/C NOT FOR ALL
A. Installation of the Stop Plate
(1) Install the stop plate (4) with the four screws (5) on the housing (2).
(2) Make sure that the segments (3) are correctly installed in the housing (2).
5. Close-up(1) Install the stop plate (4) with the four screws (5) on the housing (2).
(2) Make sure that the segments (3) are correctly installed in the housing (2).
Subtask 30-21-49-410-109-A ** ON A/C NOT FOR ALL
Pylon Anti-ice Duct