W DOC AIRBUS | AMM A320F

Reactivation of the Reservoir Low-Level Warning


TASK 29-30-00-440-003-A
Reactivation of the Reservoir Low-Level Warning


1. Reason for the Job
MMEL 29-09-05A
HYD G(B)(Y) RSVR LO LVL ALERT (FAA ONLY)
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
196BB, 197FB
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
TASK 32-12-00-410-001-A
Close the Main Gear Doors after Access
3. Job Set-up
Subtask 29-30-00-010-055-A
A. Get Access
   (1) Open the following access doors:
NOTE: You can open one of the two doors, but access is better from the RH side.
4. Procedure
Subtask 29-30-00-440-053-A
A. Reactivation of the Reservoir Low-Level Switches
   (1) Cut, remove and discard the tie-wraps which attach the cable of the deactivated low-level switch to the adjacent structure.
   (2) Remove the protective caps from the electrical connector and from the receptacle of the reservoir.
   (3) Make sure that all the electrical connections are clean and in the correct condition.
   (4) Connect the applicable electrical connector to the low-level switch of the hydraulic reservoir.
Subtask 29-30-00-810-051-A
B. Do the troubleshooting of the reservoir low-level warning-system.
Subtask 29-30-00-942-052-A
C. Remove the warning notice from the flight compartment which refers to the fault of the fluid low-level warning-system.
5. Close-up
Subtask 29-30-00-410-059-A
A. Close Access
   (1) Close the following access doors: