Removal of the Contactor - Yellow Electric Pump Supply
TASK 29-24-55-000-001-A
Removal of the Contactor - Yellow Electric Pump Supply
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 29-24-55-941-052-A
Subtask 29-24-55-020-051-A
[Rev.10 from 2021]
2026.04.01 00:27:07 UTC
Removal of the Contactor - Yellow Electric Pump Supply
WARNING:
MAKE SURE THAT NO AC OR DC POWER IS CONNECTED TO THE AIRCRAFT ELECTRICAL CIRCUITS.
THERE IS A RISK OF ELECTROCUTION IF THE AC OR DC POWER STAYS CONNECTED.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 121AL, 822 |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 29-24-55-941-052-A
A. Safety Precautions
(1) In the cockpit, on the overhead panel 35VU, make sure that these pushbutton switches are released:
Subtask 29-24-55-010-052-A (1) In the cockpit, on the overhead panel 35VU, make sure that these pushbutton switches are released:
- APU GEN
- 1 BAT 2
- GEN 1, GEN 2
- EXT PWR.
- 21VU (EMER ELEC PWR)
- 25VU (APU)
- 35VU (ELEC).
B. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) in position at the access door 822.
(2) Put a warning notice on the access door 121AL to tell persons not to connect the external power connector.
(3) Open the access door 822.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) in position at the access door 822.
(2) Put a warning notice on the access door 121AL to tell persons not to connect the external power connector.
(3) Open the access door 822.
Subtask 29-24-55-020-051-A
A. Removal of the Contactor
(1) Remove the cover (1) of the panel 107VU.
(2) Disconnect the electrical connector (4).
(3) Put a CAP - BLANKING on the connector (4) and the electrical receptacle (3).
(5) Remove the contactor (5).
(1) Remove the cover (1) of the panel 107VU.
(2) Disconnect the electrical connector (4).
(3) Put a CAP - BLANKING on the connector (4) and the electrical receptacle (3).
CAUTION:
REMOVE THE CONTACTOR ONLY AND NOT THE BASE OR THE MODULE WHERE THE WIRES ARE CONNECTED.
(4) Loosen the 6 captive screws (6) which stay in position in their housing. (5) Remove the contactor (5).
Contactors - Yellow Electric Pump Supply (3805GX, 3806GX)