Reactivation of the Yellow Electric Pump
TASK 29-24-00-440-001-A
Reactivation of the Yellow Electric Pump
MMEL 29-24-01A
YELLOW SYSTEM ELECTRIC PUMP (FAA ONLY)
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 29-24-00-865-054-A
Subtask 29-24-00-810-050-A
Subtask 29-24-00-942-052-A
[Rev.10 from 2021]
2026.04.01 00:26:54 UTC
Reactivation of the Yellow Electric Pump
FIN: 3075GX
1. Reason for the JobMMEL 29-24-01A
YELLOW SYSTEM ELECTRIC PUMP (FAA ONLY)
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM 29-24-00-810-803 | (for corrective action) |
Subtask 29-24-00-865-054-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | DOORS/CARGO | 1MJ | T12 |
| 123VU | Y HYD/ELEC/PUMP | 3802GX | AB06 |
| 123VU | Y HYD/ELEC/ELEC PUMP/NORM | 3801GX | AB03 |
Subtask 29-24-00-810-050-A
A. Do the troubleshooting procedure for the continuous operation of the Yellow electric pump TSM 29-24-00-810-803.
5. Close-upSubtask 29-24-00-942-052-A
A. Remove the warning notice from the flight compartment which refers to the fault of the Yellow electric pump.