Removal of the RAT Ground Control Unit
TASK 29-22-12-000-003-A
Removal of the RAT Ground Control Unit
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 29-22-12-865-055-A
Subtask 29-22-12-020-052-A
[Rev.10 from 2021]
2026.04.01 00:26:09 UTC
Removal of the RAT Ground Control Unit
FIN: 3GE
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 197EB |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 29-22-12-865-055-A
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 29-22-12-010-052-A 4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | HYD/RAT/CTL | 2801GE | D14 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | HYD/RAT/CTL | 2801GE | B13 |
Subtask 29-22-12-020-052-A
A. Removal of the RAT Ground Control Unit
(1) Remove the screws (2).
(2) Carefully, pull the RAT ground control unit (3) out of the Blue ground service panel (1) so that you can remove the connector.
(3) Disconnect the electrical connector (4) from the RAT ground control unit (3).
(4) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(5) Remove the screw (5), the washer (6) and the bonding strap (7) from the RAT ground control unit (3).
(6) Remove the RAT ground control unit (3) from the Blue ground service panel (1).
(1) Remove the screws (2).
(2) Carefully, pull the RAT ground control unit (3) out of the Blue ground service panel (1) so that you can remove the connector.
(3) Disconnect the electrical connector (4) from the RAT ground control unit (3).
(4) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(5) Remove the screw (5), the washer (6) and the bonding strap (7) from the RAT ground control unit (3).
(6) Remove the RAT ground control unit (3) from the Blue ground service panel (1).
RAT Ground Control Unit