W DOC AIRBUS | AMM A320F

Removal of the RAT Ground Control Unit


TASK 29-22-12-000-003-A
Removal of the RAT Ground Control Unit


FIN: 3GE
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
197EB
 C. Referenced Information
REFERENCE
DESIGNATION
3. Job Set-up
Subtask 29-22-12-865-055-A
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUHYD/RAT/CTL2801GED14
** ON A/C NOT FOR ALL
49VUHYD/RAT/CTL2801GEB13
Subtask 29-22-12-010-052-A
B. Open the access panel 197EB.
4. Procedure
Subtask 29-22-12-020-052-A
A. Removal of the RAT Ground Control Unit
   (1) Remove the screws (2).
   (2) Carefully, pull the RAT ground control unit (3) out of the Blue ground service panel (1) so that you can remove the connector.
   (3) Disconnect the electrical connector (4) from the RAT ground control unit (3).
   (4) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (5) Remove the screw (5), the washer (6) and the bonding strap (7) from the RAT ground control unit (3).
   (6) Remove the RAT ground control unit (3) from the Blue ground service panel (1).
[Rev.10 from 2021] 2026.04.01 00:26:09 UTC