Removal of the Blue Electric-Pump Supply Contactor
TASK 29-12-55-000-001-A
Removal of the Blue Electric-Pump Supply Contactor
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 29-12-55-941-050-A
Subtask 29-12-55-020-051-A
[Rev.10 from 2021]
2026.04.01 00:19:45 UTC
Removal of the Blue Electric-Pump Supply Contactor
WARNING:
ISOLATE ALL THE AIRCRAFT ELECTRICAL CIRCUITS.
FIN: 2705GJ
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 121AL, 822 |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 29-12-55-941-050-A
A. Safety Precautions
(1) Make sure that the external power connector is not connected to the aircraft receptacle (20XG) (receptacle behind the access door 121AL).
(2) Put WARNING NOTICE(S) on the access door 121AL to tell persons not to connect the external power connector.
Subtask 29-12-55-860-050-A (1) Make sure that the external power connector is not connected to the aircraft receptacle (20XG) (receptacle behind the access door 121AL).
(2) Put WARNING NOTICE(S) on the access door 121AL to tell persons not to connect the external power connector.
B. Aircraft Maintenance Configuration
(1) In the cockpit, on the overhead panel 35VU, make sure that these pushbutton switches are released:
Subtask 29-12-55-010-050-A (1) In the cockpit, on the overhead panel 35VU, make sure that these pushbutton switches are released:
- APU GEN,
- 1 BAT 2,
- GEN1, GEN2,
- EXT PWR.
- 21VU (EMER ELEC PWR),
- 25VU (APU),
- 35VU (ELEC).
C. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) in position at the access door 822.
(2) Open the access door 822.
(3) Remove the cover (1) of the panel 107VU.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) in position at the access door 822.
(2) Open the access door 822.
(3) Remove the cover (1) of the panel 107VU.
Subtask 29-12-55-020-051-A
A. Removal of the Contactor
(1) Disconnect the electrical connector (4).
(2) Put a CAP - BLANKING on the connector (4) and the electrical receptacle (3).
(4) Remove the contactor (2).
(1) Disconnect the electrical connector (4).
(2) Put a CAP - BLANKING on the connector (4) and the electrical receptacle (3).
CAUTION:
REMOVE THE CONTACTOR ONLY AND NOT THE BASE OR THE MODULE WHERE THE WIRES ARE CONNECTED.
(3) Remove the 6 screws (5) and the washers (6). (4) Remove the contactor (2).
Blue Electric-Pump Supply Contactor (2705GJ)