To Set the Transfer Valves Open for Flight
TASK 28-12-00-040-003-A
To Set the Transfer Valves Open for Flight
MMEL 28-12-01B
OVERPRESSURE PROTECTOR BETWEEN THE INNER AND THE OUTER TANK
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-12-00-941-062-A ** ON A/C NOT FOR ALL
Subtask 28-12-00-040-054-A ** ON A/C NOT FOR ALL
Subtask 28-12-00-860-066-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.05 07:03:14 UTC
To Set the Transfer Valves Open for Flight
ZONE: 210
FIN: 27QM ** ON A/C NOT FOR ALL
FIN: 28QM ** ON A/C NOT FOR ALL
FIN: 29QM ** ON A/C NOT FOR ALL
FIN: 30QM ** ON A/C NOT FOR ALL
1. Reason for the JobFIN: 27QM ** ON A/C NOT FOR ALL
FIN: 28QM ** ON A/C NOT FOR ALL
FIN: 29QM ** ON A/C NOT FOR ALL
FIN: 30QM ** ON A/C NOT FOR ALL
MMEL 28-12-01B
OVERPRESSURE PROTECTOR BETWEEN THE INNER AND THE OUTER TANK
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-11-28-650-003-A | Pressure Refuel with Automatic Control |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 28-00-00-910-001-A | Fuel Safety Procedures |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
Subtask 28-12-00-941-062-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(2) In the cockpit, put a WARNING NOTICE(S) in position to tell persons not to operate the flight controls.
Subtask 28-12-00-650-058-A ** ON A/C NOT FOR ALL WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
(1) You must obey the fuel safety procedures when you do work on the fuel system (Ref. AMM TASK 28-00-00-910-001). (2) In the cockpit, put a WARNING NOTICE(S) in position to tell persons not to operate the flight controls.
B. Fuel Configuration
(1) Refuel the aircraft with the necessary quantity of fuel (Ref. AMM TASK 12-11-28-650-003).
(2) Before you continue with this procedure make sure that:
Subtask 28-12-00-860-065-A ** ON A/C NOT FOR ALL (1) Refuel the aircraft with the necessary quantity of fuel (Ref. AMM TASK 12-11-28-650-003).
(2) Before you continue with this procedure make sure that:
- the quantity of fuel onboard the aircraft is correct
- the refuel/defuel panel door is closed.
C. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (ECAM only) (Ref. AMM TASK 31-60-00-860-001).
(3) On the ECAM control panel, push the FUEL pushbutton switch to show the FUEL page on the ECAM lower display unit.
Subtask 28-12-00-865-058-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (ECAM only) (Ref. AMM TASK 31-60-00-860-001).
(3) On the ECAM control panel, push the FUEL pushbutton switch to show the FUEL page on the ECAM lower display unit.
D. Table of the circuit breakers used in this procedure:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 102QM (PROTECTOROVERPRESSURE, L WING TK) | |||
| 49VU | FUEL/XFR VALVE1/WING/R | 2QP | A11 |
| 121VU | FUEL/XFR VALVE2/WING/R | 4QP | M23 |
| FOR FIN: 103QM (PROTECTOROVERPRESSURE, R WING TK) | |||
| 49VU | FUEL/XFR VALVE1/WING/L | 1QP | A10 |
| 121VU | FUEL/XFR VALVE2/WING/L | 3QP | M22 |
Subtask 28-12-00-040-054-A ** ON A/C NOT FOR ALL
A. To Set the LH Wing Transfer Valves 27QM and 28QM Open for Flight
(1) If overpressure protector 102QM or 103QM is damaged do this procedure:
(2) Monitor the wing fuel quantity indications on the ECAM display unit. Make sure the quantity of fuel in the wing tank inner cell increases as fuel moves from the outer cell. The LH wing transfer valves are now set to the open position and the aircraft is ready for flight.
Subtask 28-12-00-040-055-A ** ON A/C NOT FOR ALL (1) If overpressure protector 102QM or 103QM is damaged do this procedure:
NOTE: The circuit breakers must be opened and closed in the sequence given.
| ACTION | RESULT |
|---|---|
| 1.On the panel 49VU: | |
| |
|
|
| 2.On the panel 121VU: | |
| |
|
|
| 3.On the panel 49VU: | |
|
|
4.On the panel 121VU:
| |
NOTE: The wing transfer valves will close again if the refuel/defuel panel door is opened.
B. To Set the RH Wing Transfer Valves 29QM and 30QM Open for Flight
(1) If overpressure protector 102QM or 103QM is damaged do this procedure:
(2) Monitor the wing fuel quantity indications on the ECAM display unit. Make sure the quantity of fuel in the wing tank inner cell increases as fuel moves from the outer cell. The RH wing transfer valves are now set to the open position and the aircraft is ready for flight.
5. Close-up(1) If overpressure protector 102QM or 103QM is damaged do this procedure:
NOTE: The circuit breakers must be opened and closed in the sequence given.
| ACTION | RESULT |
|---|---|
| 1.On the panel 49VU: | |
| |
|
|
| 2.On the panel 121VU: | |
| |
|
|
| 3.On the panel 49VU: | |
|
|
4.On panel 121VU:
| |
NOTE: The wing transfer valves will close again if the refuel/defuel panel door is opened.
Subtask 28-12-00-860-066-A ** ON A/C NOT FOR ALL
A. Aircraft Configuration
(1) Do the EIS stop procedure (Ref. AMM TASK 31-60-00-860-002).
(2) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
(3) Make a note in the aircraft technical log that the applicable transfer valves are set to the open position.
Subtask 28-12-00-942-065-A ** ON A/C NOT FOR ALL (1) Do the EIS stop procedure (Ref. AMM TASK 31-60-00-860-002).
(2) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
(3) Make a note in the aircraft technical log that the applicable transfer valves are set to the open position.
B. Removal of the Equipment
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the WARNING NOTICE(S).