Removal of the PPU Adaptor Plate
TASK 27-81-42-000-001-A
Removal of the PPU Adaptor Plate
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 27-81-42-941-050-A
Subtask 27-81-42-020-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:56:27 UTC
Removal of the PPU Adaptor Plate
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
1. Reason for the JobSelf Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 4M (13 FT) |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [6048CM] (SLAT APPU ADAPTER) | |
| 522UB | |
| FOR [6098CM] (SLAT APPU ADAPTER) | |
| 622UB | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 27-80-00-866-005-A | Retracting the Slats on the Ground |
| TASK 27-81-18-000-001-A | Removal of the Asymmetry-Position Pick-Off Unit |
Subtask 27-81-42-941-050-A
A. Safety Precautions
(1) Put the SAFETY BARRIER(S) in position.
(2) Put the WARNING NOTICE(S) in position to tell persons not to operate the flap/slat controls.
Subtask 27-81-42-860-050-A (1) Put the SAFETY BARRIER(S) in position.
(2) Put the WARNING NOTICE(S) in position to tell persons not to operate the flap/slat controls.
B. Aircraft Maintenance Configuration
(1) Make sure that the slats are fully retracted (Ref. AMM TASK 27-80-00-866-005).
(2) Make sure that the 98D27803500001 LOCKING TOOL ZERO POS or 98D27803500002 LOCKING TOOL ZERO POS is installed on the flap/slat control lever on the panel 114VU.
(3) Remove the safety collar from the circuit breakers 9CV and 11CV.
Subtask 27-81-42-865-050-A (1) Make sure that the slats are fully retracted (Ref. AMM TASK 27-80-00-866-005).
(2) Make sure that the 98D27803500001 LOCKING TOOL ZERO POS or 98D27803500002 LOCKING TOOL ZERO POS is installed on the flap/slat control lever on the panel 114VU.
(3) Remove the safety collar from the circuit breakers 9CV and 11CV.
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 27-81-42-010-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/SLT/CTL AND MONG/SYS1 | 5CV | B06 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/SLT/CTL AND MONG/SYS1 | 5CV | B01 |
| ** ON A/C ALL | |||
| 121VU | FLIGHT CONTROLS/WTB/SLT/SYS2 | 11CV | P19 |
| 121VU | FLIGHT CONTROLS/SLT/CTL/SYS2 | 7CV | R21 |
| 122VU | FLIGHT CONTROLS/WTB/SLT/SYS1 | 9CV | S06 |
D. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT) in position:
(a) FOR [6048CM] (SLAT APPU ADAPTER)
below zone 510
(b) FOR [6098CM] (SLAT APPU ADAPTER)
below zone 610.
(2) Remove the access panels:
(a) FOR [6048CM] (SLAT APPU ADAPTER)
remove 522UB
(b) FOR [6098CM] (SLAT APPU ADAPTER)
remove 622UB.
4. Procedure(1) Put the ACCESS PLATFORM 4M (13 FT) in position:
(a) FOR [6048CM] (SLAT APPU ADAPTER)
below zone 510
(b) FOR [6098CM] (SLAT APPU ADAPTER)
below zone 610.
(2) Remove the access panels:
(a) FOR [6048CM] (SLAT APPU ADAPTER)
remove 522UB
(b) FOR [6098CM] (SLAT APPU ADAPTER)
remove 622UB.
Subtask 27-81-42-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the PPU Adaptor Plate
(1) Remove the Asymmetry-Position Pick-off Unit (APPU) (Ref. AMM TASK 27-81-18-000-001).
(2) Remove the retaining ring (7) and the pin (5).
(3) Loosen the screws (2) and turn the cover plate (3) counterclockwise to get access to the nuts (4).
(4) Remove the nuts (4) from the bolts (8).
(5) Hold the slat torque-shaft and remove the PPU adaptor plate (1) together with the cover plate (3).
(6) Remove the bolts (8) and the locking ring (6).
Subtask 27-81-42-020-051-B ** ON A/C NOT FOR ALL (1) Remove the Asymmetry-Position Pick-off Unit (APPU) (Ref. AMM TASK 27-81-18-000-001).
(2) Remove the retaining ring (7) and the pin (5).
(3) Loosen the screws (2) and turn the cover plate (3) counterclockwise to get access to the nuts (4).
(4) Remove the nuts (4) from the bolts (8).
(5) Hold the slat torque-shaft and remove the PPU adaptor plate (1) together with the cover plate (3).
(6) Remove the bolts (8) and the locking ring (6).
A. Removal of the PPU Adaptor Plate
(1) Remove the Asymmetry-Position Pick-off Unit (APPU) (Ref. AMM TASK 27-81-18-000-001).
(2) Remove the retaining ring (5) and the pin (3).
(3) Remove the nuts (2) from the bolts (6).
(4) Hold the slat torque-shaft and remove the PPU adaptor plate (1).
(5) Remove the bolts (6) and the locking ring (4).
(1) Remove the Asymmetry-Position Pick-off Unit (APPU) (Ref. AMM TASK 27-81-18-000-001).
(2) Remove the retaining ring (5) and the pin (3).
(3) Remove the nuts (2) from the bolts (6).
(4) Hold the slat torque-shaft and remove the PPU adaptor plate (1).
(5) Remove the bolts (6) and the locking ring (4).
Position Pick-Off Unit Adaptor-Plate 6048CM(6098CM)