Detailed Inspection of Mechanical Control Linkage in FIN
TASK 27-21-00-210-003-A
Detailed Inspection of Mechanical Control Linkage in FIN
Refer to the MPD TASK: 272100-07
DETAILED INSPECTION OF MECHANICAL CONTROL LINKAGE IN FIN
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 27-21-00-941-059-A
Subtask 27-21-00-210-054-A
Subtask 27-21-00-410-058-A
[Rev.10 from 2021]
2026.03.31 23:48:04 UTC
Detailed Inspection of Mechanical Control Linkage in FIN
ZONE: 325
1. Reason for the JobRefer to the MPD TASK: 272100-07
DETAILED INSPECTION OF MECHANICAL CONTROL LINKAGE IN FIN
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 10M (33 FT) - ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 325 | VERTICAL STABILIZER TRAILING EDGE |
| 325BL, 325CL, 325DL, 325EL |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 27-21-00-941-059-A
A. Put the WARNING NOTICE(S) in position to tell persons not to pressurize the hydraulic systems.
Subtask 27-21-00-010-058-A B. Get Access
(1) Put an ACCESS PLATFORM 10M (33 FT) - ADJUSTABLE in position at zone 325.
(2) Open the access doors 325BL 325CL 325DL 325EL.
4. Procedure(1) Put an ACCESS PLATFORM 10M (33 FT) - ADJUSTABLE in position at zone 325.
(2) Open the access doors 325BL 325CL 325DL 325EL.
Subtask 27-21-00-210-054-A
A. Detailed inspection
(1) Make sure that there is no corrosion, no wear, no damage, no crack, no disconnection on the control rods that follow:
(2) Make sure that there is no corrosion, no wear, no damage, no crack on all the control linkage components (1), (2), (3), (4), (5), (6), (7) and (9).
5. Close-up(1) Make sure that there is no corrosion, no wear, no damage, no crack, no disconnection on the control rods that follow:
- the rod (11) which connects the upper bellcrank (8) to the centering spring rod (1),
- the rod (2) which connects the centering spring rod (1) to the travel limitation unit (10),
- the rod (9) which connects the upper bellcrank (8) to the travel limitation unit (10),
- the centering spring rod (1).
(2) Make sure that there is no corrosion, no wear, no damage, no crack on all the control linkage components (1), (2), (3), (4), (5), (6), (7) and (9).
Subtask 27-21-00-410-058-A
A. Close Access
(1) Close the access doors 325BL 325CL 325DL 325EL.
(2) Remove the access platform(s).
Subtask 27-21-00-942-066-A (1) Close the access doors 325BL 325CL 325DL 325EL.
(2) Remove the access platform(s).
B. Remove the WARNING NOTICE(S).
Component Location