Removal of the Check Valve
TASK 26-23-21-000-001-A
Removal of the Check Valve
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 26-23-21-010-050-A ** ON A/C NOT FOR ALL
Subtask 26-23-21-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:46:15 UTC
Removal of the Check Valve
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 825 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 26-23-21-010-050-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the FWD cargo-compartment door 825.
(2) Open the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
(3) Remove the protection panel 132MW.
Subtask 26-23-21-865-050-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the FWD cargo-compartment door 825.
(2) Open the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
(3) Remove the protection panel 132MW.
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/CARGO FIRE/EXTIG/BTL2 | 8WX | C05 |
| 49VU | AIR COND/CARGO/FIRE/EXTIG/BTL1 | 1WX | C04 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/CARGO FIRE/EXTIG/BTL2 | 8WX | C04 |
| 49VU | AIR COND/CARGO/FIRE/EXTIG/BTL1 | 1WX | C03 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/CARGO/FIRE/EXTIG | 1WX | T19 |
Subtask 26-23-21-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Check Valve
(2) Loosen the nut (4) and disconnect the pipe (5) from the check valve (3).
(3) Remove the check valve (3).
(4) Put the PLUG-BLANKING in each disconnected line end.
(5) Put PLUG - BLANKING on the open ports of the check valve (3).
NOTE: The removal procedure is the same for the check valves 5016WM and 5017WM.
(1) Loosen the nut (2) and disconnect the pipe (1) from the check valve (3). (2) Loosen the nut (4) and disconnect the pipe (5) from the check valve (3).
(3) Remove the check valve (3).
(4) Put the PLUG-BLANKING in each disconnected line end.
(5) Put PLUG - BLANKING on the open ports of the check valve (3).
Check Valve