W DOC AIRBUS | AMM A320F

Removal of the Check Valve


TASK 26-23-21-000-001-A
Removal of the Check Valve


FIN: 5016WM ** ON A/C NOT FOR ALL
FIN: 5017WM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
825
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
F Check Valve ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 26-23-21-010-050-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the FWD cargo-compartment door 825.
   (2) Open the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
   (3) Remove the protection panel 132MW.
Subtask 26-23-21-865-050-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/CARGO FIRE/EXTIG/BTL28WXC05
49VUAIR COND/CARGO/FIRE/EXTIG/BTL11WXC04
** ON A/C NOT FOR ALL
49VUAIR COND/CARGO FIRE/EXTIG/BTL28WXC04
49VUAIR COND/CARGO/FIRE/EXTIG/BTL11WXC03
** ON A/C NOT FOR ALL
122VUAIR COND/CARGO/FIRE/EXTIG1WXT19
4. Procedure
Subtask 26-23-21-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Check Valve
NOTE: The removal procedure is the same for the check valves 5016WM and 5017WM.
   (1) Loosen the nut (2) and disconnect the pipe (1) from the check valve (3).
   (2) Loosen the nut (4) and disconnect the pipe (5) from the check valve (3).
   (3) Remove the check valve (3).
   (4) Put the PLUG-BLANKING in each disconnected line end.
   (5) Put PLUG - BLANKING on the open ports of the check valve (3).